Text |
| 2021-12-14 11:13:27 | BUILDING REVIEW APPROVED WITH PROVISO. | | | NOTE: PROVIDE INFORMATION FOR REVIEW PRIOR TO | | | INSPECTIONS TO AVOID CONFLICTS/DELAYS: | | | 1-REVISE ENERGY CALCULATIONS: A)NEED COMPLETE AND | | | CORRECT INFORMATION. OWNER'S NAME, BUILDER'S | | | NAME,CORRECT PERMIT OFFICE IS WEST PALM BEACH, CORRECT | | | JURISDICTION IS 604700. B)REVISE WALL TYPE ON ITEM | | | 10(B) TO MATCH PLANS. PLANS DON'T SPECIFY WOOD FRAME | | | WALL. C)REVISE DOOR INFORMATION ON PAGE 4. PLANS DON'T | | | SHOW ANY WOOD DOOR ON THE EAST SIDE. D)REVISE WINDOWS | | | OVERHANG DEPTH & SEPARATION TO MATCH PLANS. | | | | | | 2-DEFERRED SUBMITTAL: PROVIDE SHOP DRAWINGS (SIGNED & | | | SEALED) FOR HAMBRO ROOF & FLOOR SYSTEMS SHOWING ALL | | | FRAMING MEMBERS AND CONNECTORS. | | | | | | 3- PROVIDE PRODUCT APPROVAL FOR: | | | A)ICF WALL SYSTEM SPECIFIED ON PLANS. | | | B)FLAT ROOF ASSEMBLY. AND, CLEARLY MARK ASSEMBLY TO BE | | | INSTALLED. | | | C)WINDOW MULLION CLEARLY SPECIFY ALL MULLION SIZES TO | | | BE USED. | | | D) ALL DOORS AND WINDOWS TYPES SHOWN ON PLANS. | | | | | | 4-ENGINEER OF RECORD TO REVIEW/APPROVE IN WRITING (NOT | | | SIGNING AND SEALING) ALL PRODUCT APPROVALS. | | | | | | 5-PROVIDE ICC EVALUATION REPORT FOR THE SPRAY FOAM | | | INSULATION. | | | NOTE: ENGINEER OF RECORD TO REVIEW/APPROVE PRIOR TO | | | SUBMITTAL. |
|