| Plan Review Notes For Permit 21081506 |
| Permit Number |
21081506 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-10-13 17:28:17 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT DETAILED STRUCTURAL DRAWINGS FOR THE MASONRY | | | COLUMNS AND THE FOUNDATIONS SUPPORTING THEM. SPECIFY | | | THE STEEL REINFORCING SIZE AND LOCATIONS. FBC | | | AMENDMENTS 107.2.1 | | | 2) SPECIFY THE WIND DATA ON THE DRAWINGS. FBC-R 301 | | | 3) PROVIDE DETAILS OF THE FENCE SECTIONS AND GATES. FBC | | | AMENDMENTS 107.2.1 | | | 4) THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | THE DESIGN IS REQUIRED TO BE ON THE DRAWINGS. FBC | | | AMENDMENTS 107.2.1 - INFORMATION ON CONSTRUCTION | | | DOCUMENTS. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. |
|