| Date |
Text |
| 2021-10-13 17:30:05 | 2ND REVIEW FBC-2020 PLUMBING |
| | PERMIT- 21081096 |
| | 10/13/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE |
| | IST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES IN |
| | PARANTHESES. |
| | |
| | 1) FAILED. SHEET A.1: FAIR HOUSING ACCESSIBILITY |
| | GUIDELINES: BECAUSE THE BUILDING WAS CONSTRUCTED IN |
| | ACCORDANCE WITH THE ACCESSIBILITY REQUIREMENTS OF THE |
| | FAIR HOUSING ACT AND THE DESIGN GUIDELINES FOR USABLE |
| | BATHROOMS IN DWELLING UNITS, THE ALTERATIONS THAT ARE |
| | PROPOSED IN THE BATHROOM SHALL ALSO BE IN COMPLIANCE |
| | WITH THE FAIR HOUSING ACT. THE FAIR HOUSING |
| | ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA |
| | ACCESSIBILITY CODE- 2017 SIXTH EDITION. REFER TO |
| | REQUIRMENT 7 USUABLE KITCHENS AND BATHROOMS AND PAGE |
| | 7.33 IN THE FAIR HOUSING ACT DESIGN MANUAL. |
| | THE ARCHITECT SHALL SPECIFY WHICH USABLE BATHROOM |
| | SPECIFICATION TYPE A OR B WAS CHOSEN AS THE ORIGINAL |
| | DESIGN. PLEASE REFER TO PAGES 7.34- 7.39 OF THE FAIR |
| | HOUSING DESIGN ACT MANUAL FOR EXPLANATORY INFORMATION |
| | ON SPECIFICATION A & B. AN ENLARGED DIMENSIONED |
| | BATHROOM DRAWING WITH ELEVATION DETAILS WILL BE |
| | REQUIRED IN ORDER TO VERIFY COMPLIANCE FOR THE NEW |
| | FIXTURE INSTALLATIONS- SECTION 107.2.1 WPB. (PLEASE |
| | PROVIDE THE SPECIFICATION TYPE A OR B ON THE PLAN.) |
| | |
| | 4) FAILED. BASED ON EITHER SPECIFICATION A OR B PLEASE |
| | REFER TO PAGES 6.12- 6.13 AND PROVIDE AND ELEVATION |
| | DETAIL SHOWING THE SHOWER CONTROLS LOCATION, AND THE |
| | GRAB BAR AND SEAT REINFORCEMENT DETAILS. SHOW THE |
| | LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF |
| | REINFORCEMENT MATERIAL TO BE USED. SEE SECTION 603.1 |
| | FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS. |
| | (SHOWER CONTROLS LOCATION AND GRAB BAR REINFORCEMENT |
| | DETAILS NOT PROVIDED.) |
| | |
| | PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE |
| | GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND |
| | DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE |
| | A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE |
| | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET |
| | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY |
| | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO |
| | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF |
| | REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, |
| | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A |
| | COPY OF THE FAIR HOUSING AFFIDAVIT. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |