| 2021-09-09 17:06:33 | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21081002 |
| | |
| | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| | SHALL COMPLY WITH THE MATERIALS AND METHODS |
| | REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| | |
| | 1- IF REROOFING THE FLAT ROOF, THEN CLEARLY MARK WHICH |
| | APPROVED ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY |
| | COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | NOTE: NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE |
| | DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND |
| | SEALED RAS 117 CALCULATIONS ARE REQUIRED. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NO SPECIFICATIONS OF WHICH APPROVED |
| | ASSEMBLY FROM NOA 17-1004.09 SUBMITTED IS GOING TO BE |
| | INSTALLED. ONLY ENGINEERING SHOWING THE FLAT ROOF WIND |
| | LOADS FOR EACH ROOF ZONE WAS PROVIDED. IF THE SELECTED |
| | ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF |
| | ZONES, THEN NEED SIGNED AND SEALED RAS 117 |
| | CALCULATIONS. SEE GENERAL LIMITATION #7 ON LAST PAGE OF |
| | NOA SUBMITTED. |
| | |
| | 3- SPECIFY ROOF PITCH, BUILDING MEAN HEIGHT AS REQUIRED |
| | BY CITY POLICY FOR ALL ROOFING PERMITS. SEC. 107.02.1 |
| | CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NO ADDRESSED. |
| | |
| | 4- PROVIDE SPECIFICATIONS CLEARLY SHOWING HOW COMPLYING |
| | WITH THE NEW 2020 CODE REQUIREMENT FOR ROOFING |
| | UNDERLAYMENT SEC. 1507.1.1.1 FBC-BUILDING. |
| | NOTE: PROVIDE PRODUCT APPROVAL FOR ROOF SHINGLES |
| | UNDERLAYMENT TO BE USED. FAC 61G20-3.001. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NO ADDRESSED. |
| | |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |