2021-08-27 10:38:40RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21081002
  
 NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK
 SHALL COMPLY WITH THE MATERIALS AND METHODS
 REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 1- SCOPE OF WORK IS NOT CLEAR. PERMIT APPLICATION
 SPECIFY REROOF OF SHINGLES. PRODUCT APPROVALS FOR
 SHINGLES AND MODIFIED BITUMEN WERE SUBMITTED. IS THERE
 A LOW ROOF TO BE RE-ROOF ALSO?. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 2- IF REROOFING THE FLAT ROOF, THEN CLEARLY MARK WHICH
 APPROVED ASSEMBLY IS GOING TO BE INSTALLED TO VERIFY
 COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL.
 NOTE: NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE
 DESIGN PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND
 SEALED RAS 117 CALCULATIONS ARE REQUIRED.
  
 3- SPECIFY ROOF PITCH, BUILDING MEAN HEIGHT AS REQUIRED
 BY CITY POLICY FOR ALL ROOFING PERMITS. SEC. 107.02.1
 CITY AMENDMENTS.
  
 4- PROVIDE SPECIFICATIONS CLEARLY SHOWING HOW COMPLYING
 WITH THE NEW 2020 CODE REQUIREMENT FOR ROOFING
 UNDERLAYMENT SEC. 1507.1.1.1 FBC-BUILDING.
 NOTE: PROVIDE PRODUCT APPROVAL FOR ROOF SHINGLES
 UNDERLAYMENT TO BE USED. FAC 61G20-3.001.
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  