| Plan Review Notes For Permit 21080875 |
| Permit Number |
21080875 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-09-28 16:33:47 | REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) CANNOT PERFORM A FULL PLAN REVIEW - SOME | | | ARCHITECTURAL DRAWINGS APPEAR TO BE MISSING FROM | | | PROJECTDOX. I SEE NO STRUCTURAL DRAWINGS. I SEE NO | | | ACCESSIBLE RESTROOM DETAILS. I DO NOT SEE A LIFE SAFETY | | | PLAN ETC. | | | 2) SEPARATE PERMITS ARE REQUIRED FOR THE SITE WORK, | | | DUMPSTER ENCLOSURE, SIGNS, PARKING LOT ETC. | | | 3) ACCESSIBLE PARKING SPACE SHOULD BE 12' WIDE PER FBC | | | A 502.2 | | | 4) PLEASE PROVIDE PRODUCT APPROVALS FOR THE EXTERIOR | | | WINDOWS AND DOORS. ALL PRODUCT APPROVALS NEED TO BE | | | REVIEWED AND MARKED APPROVED BY THE DESIGNER OF RECORD | | | OR BE LISTED BY THE PRODUCT APPROVAL NUMBER ON THE | | | DRAWINGS, FBC WPB 107 | | | |
|