Notes
Date Text
2022-01-13 14:31:05FBC- 2020 ACCESSIBILITY- STANDARD ROLL-IN TYPE SHOWERS:
  
 1) SEC. 607.8: THRESHOLDS IN ROLL-IN TYPE SHOWER
 COMPARTMENTS SHALL BE 1/2-INCH HIGH MAXIMUM IN
 ACCORDANCE WITH 303.
  
 2) SEC. 608.2.2: STANDARD ROLL-IN TYPE SHOWER
 COMPARTMENTS SHALL BE 30 INCHES WIDE MINIMUM BY 60
 INCHES DEEP MINIMUM CLEAR INSIDE DIMENSIONS MEASURED AT
 CENTER POINTS OF OPPOSING SIDES AND SHALL HAVE A 60
 INCHES WIDE MINIMUM ENTRY ON THE FACE OF THE SHOWER
 COMPARTMENT.
  
 3) SEC. 608.2.2.1 CLEARANCE UNDER THE EXCEPTION- "A
 LAVATORY COMPLYING WITH 606 SHALL BE PERMITTED ON ONE
 30 INCH WIDE MINIMUM SIDE OF THE CLEARANCE PROVIDED
 THAT IT IS NOT ON THE SIDE OF THE CLEARANCE ADJACENT TO
 THE CONTROLS OR, WHERE PROVIDED, NOT ON THE SIDE OF THE
 CLEARANCE ADJACENT TO THE SHOWER SEAT.