| Plan Review Notes For Permit 21080869 |
| Permit Number |
21080869 |
|
| Review Stop |
P |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2021-12-22 11:03:44 | FBC- 2020 ACCESSIBILITY PROVISOS- STANDARD ROLL-IN TYPE | | | SHOWERS: | | | | | | 1) SEC. 607.8: THRESHOLDS IN ROLL-IN TYPE SHOWER | | | COMPARTMENTS SHALL BE 1/2-INCH HIGH MAXIMUM IN | | | ACCORDANCE WITH 303. | | | | | | 2) SEC. 608.2.2: STANDARD ROLL-IN TYPE SHOWER | | | COMPARTMENTS SHALL BE 30 INCHES WIDE MINIMUM BY 60 | | | INCHES DEEP MINIMUM CLEAR INSIDE DIMENSIONS MEASURED AT | | | CENTER POINTS OF OPPOSING SIDES AND SHALL HAVE A 60 | | | INCHES WIDE MINIMUM ENTRY ON THE FACE OF THE SHOWER | | | COMPARTMENT. | | | | | | 3) SEC. 608.2.2.1 CLEARANCE UNDER THE EXCEPTION- "A | | | LAVATORY COMPLYING WITH 606 SHALL BE PERMITTED ON ONE | | | 30 INCH WIDE MINIMUM SIDE OF THE CLEARANCE PROVIDED | | | THAT IT IS NOT ON THE SIDE OF THE CLEARANCE ADJACENT TO | | | THE CONTROLS OR, WHERE PROVIDED, NOT ON THE SIDE OF THE | | | CLEARANCE ADJACENT TO THE SHOWER SEAT. |
|