Plan Review Notes
Plan Review Notes For Permit 21080815
Permit Number 21080815
Review Stop M
Sequence Number 1
Notes
Date Text
2022-11-21 16:21:031ST REVIEW FMC
 PERMIT: 21080815
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) FORM R405-2020 ITEM NUMBER 5 ASKS IF THIS IS A WORST
 CASE. THIS DOES NOT MEET THE EXCEPTION FOR WORST CASE.
 PLEASE CORRECT THIS ITEM. FEC R405.4.2.1 ??? EXCEPTION
  
 2) THE HVAC CALCULATIONS HAVE THE REFERENCE CITY AS
 MIAMI, PLEASE CHANGE TO WEST PALM BEACH. IT ALSO DOES
 NOT HAVE THE PROJECT ADDRESS LISTED. PLEASE SHOW THIS
 CALCULATION IS FOR THE PROJECT ADDRESS. FBC 107.3.5
  
 3) SHEET M-1: PLEASE PROVIDE THE CFM???S OF THE RANGE
 HOOD FAN. FRC M1503.4
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy