| 2021-11-22 13:26:20 | BUILDING PLAN REVIEW |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | 2ND REVIEW |
| | |
| | NOTICE: A SEPERATE ROOFING PERMIT IS REQUIRED. SEE |
| | PROVISO ON PLAN PAGE A102. |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | ADDRESS COMMENTS FROM 1ST REVIEW: |
| | |
| | |
| | 3.PROVIDE A SOILS REPORT. |
| | R401.4 SOIL TESTS. |
| | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL |
| | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, |
| | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE |
| | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL |
| | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE |
| | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. |
| | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN |
| | APPROVED METHOD. |
| | 1803.2 INVESTIGATIONS REQUIRED. |
| | GEOTECHNICAL INVESTIGATIONS SHALL BE CONDUCTED IN |
| | ACCORDANCE WITH SECTIONS 1803.3 THROUGH 1803.5. |
| | WHERE REQUIRED BY THE BUILDING OFFICIAL OR WHERE |
| | GEOTECHNICAL INVESTIGATIONS INVOLVE IN-SITU TESTING, |
| | LABORATORY TESTING OR ENGINEERING CALCULATIONS, SUCH |
| | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED |
| | DESIGN PROFESSIONAL. |
| | |
| | NOTICE: |
| | BASED ON THE OFFICIAL ZONING MAP REFERRED TO IN SECTION |
| | 53-2 OF CHAPTER 53 OF THE CITY CODE OF WEST PALM BEACH, |
| | FLORIDA, 1962, ADOPTED JUNE 15, 1964, YOUR PROPERTY, |
| | LOCATED AT 4210 WASHINGTON RD., W.P.B., FL, IS LOCATED |
| | IN AN AREA OF QUESTIONABLE SOILS AND REQUIRES |
| | INVESTIGATION BY A GEOTECHNICAL ENGINEER WITH ITS |
| | SUBSEQUENT SOILS REPORT AND DENSITY TESTING. |
| | THIS ONLY RELIEVES YOU FROM THE STATUTORY REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE. THERE MAY BE OTHER |
| | ENTITIES, SUCH AS YOUR DESIGN PROFESSIONAL OR YOUR |
| | LENDING INSTITUTION THAT MAY REQUIRE THE ABOVE |
| | MENTIONED INVESTIGATION. |
| | |
| | |
| | 5.UNDER-FLOOR CRAWL SPACE SHALL COMPLY WITH R408: HOW |
| | WILL THIS BE ADDRESSED? PROVIDE A DETAIL OR NARRATIVE. |
| | 5A) R408.1VENTILATION |
| | 5B) R408.2 OPENINGS FOR UNDER-FLOOR VENTILATION. |
| | 5C) R408.3 UNVENTED CRAWL SPACE. |
| | 5D) R408.4 ACCESS. |
| | |
| | NEW COMMENT: |
| | |
| | 6. PROVIDE PRODUCT APPROVALS FOR NEW WINDOW MULLIONS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | PLEASE UPLOAD YOUR DOCUMENTS TO PROJECT DOX. |
| | DO NOT E-MAIL THEM TO THE PLANS EXAMINER. |
| | |
| | |