| 2022-06-27 16:05:06 | NFIP PLAN REVIEW |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 |
| | |
| | 3RD REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | RE: CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC) |
| | COMMENTS PER FB107. |
| | |
| | NOTICE: |
| | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. |
| | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN |
| | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER |
| | PREVIOUS COMMENTS. |
| | |
| | 1. SECTION AA) GARAGE SQUARE FOOTAGE STATES 575SF. PLAN |
| | PAGE A100. STATES GARAGE IS 667SF. |
| | (PLAN REVIEW COMMENTS BY CARLOS CORDEO-LUZA STATES THE |
| | GARAGE IS 647. ENTER CORRECT DATA ON LINE A9A) OF EC) |
| | |
| | 2. SECTION A9B) NUMBER OF FLOOD OPENINGS STATES N/A. |
| | PLAN PAGE AOOO SHOWS 2 FLOOD OPENINGS. (NOT CORRECTED) |
| | |
| | 3. A9C) TOTAL NET AREA STATES N/A. THIS DATA WILL BE |
| | FROM THE TYPE OF FLOOD VENTS INSTALLED. ENGINEERED OR |
| | NON-ENGINEERED. (NOT CORRECTED) |
| | |
| | 4. SECTION A9D) ENGINEERED FLOOD OPENINGS STATES NO. IF |
| | NON-ENGINEERED FLOOD OPENINGS ARE INSTALLED, PROVIDE A |
| | DETAIL BY A QUALIFIED DESIGN PROFESSIONAL, SIGNED AND |
| | SEALED. (INCORRECT DATA STILL ENETERD) |
| | |
| | 5. SECTION C2D) TOP OF GARAGE FLOOR STATES 7.7FT. PLAN |
| | PAGE A100 STATES 6.6FT. (INCORRECT DATA STILL ENETERD) |
| | |
| | 6. C2E) LOWEST ELEVATION OF MACHINERY STATES N/A. |
| | MACHINERY SERVICING THE BUILDING SHALL BE AT OR ABOVE |
| | THE DFE OF 8.0FT NAVD. (ENTER CORRECT DATA) |
| | |
| | 7. C2F) LOWEST ADJACENT GRADE. REQUIRED. (DATA ENTERED |
| | APPEARS TO BE INCORRECT. PLEASE REFERENCE SITE DRAINAGE |
| | PLAN PAGE C-1 FOR DATA) |
| | |
| | 8. C2G) HIGHEST ADJACENT GRADE. REQUIRED. (DATA ENTERED |
| | APPEARS TO BE INCORRECT. PLEASE REFERENCE SITE DRAINAGE |
| | PLAN PAGE C-1 FOR DATA) |
| | |
| | 9. SECTION D COMMENTS: TYPE OF EQUIPMENT AND LOCATION |
| | REQUIRED. (SEE DIRECTIONS IN COMMENTS NARRATIVE BLOCK) |
| | (NOT ADDRESSED) |
| | |
| | 10. |
| | |
| | PROVISO: PLAN PAGE S1 - UNDER CONSTRUCTION EC REQUIRED |
| | AT PLACEMENT OF 1ST FLOOR. |
| | |
| | C/O HOLD: FINISHED CONSTRUCTION EC REQUIRED PRIOR TO |
| | C/O. |
| | |
| | NEW COMMENT: |
| | |
| | 11. C2B) DATA MISSING. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |
| | |