| Date |
Text |
| 2021-09-08 08:30:39 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2020 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 21080700 |
| | ADD: 6108 S. DIXIE HWY. # 1 |
| | CONT: NEITA & ASSOCIATES |
| | TEL: 561-602-0009 |
| | E-MAIL: [email protected] |
| | |
| | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. SEPT. 08/2021 |
| | ACTION: DENIED |
| | |
| | 1) THE PERMIT VALUE OF $5,000.00 DOLLARS IS LOW FOR THE |
| | DESCRIPTION OF WORK. 109.3 BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 2) SHEET A101 THE FLOOR PLAN SHOWS NEW LOW WALLS AT THE |
| | TAKEOUT AREA. THERE ARE LOW WALLS AT 34 INCHES AND A |
| | 42-INCH-HIGH WALL IT APPEARS AT THE POINT OF SALES. |
| | 2020 FBC-ACCESSIBILITY CODE SHOW COMPLIANCE WITH THE |
| | ACCESS. CODE 305.5 POSITION. UNLESS OTHERWISE |
| | SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE |
| | POSITIONED FOR EITHER A FORWARD OR PARALLEL APPROACH TO |
| | AN ELEMENT. |
| | 904.4 SALES AND SERVICE COUNTERS. SALES COUNTERS AND |
| | SERVICE COUNTERS SHALL COMPLY WITH 904.4.1 OR 904.4.2. |
| | THE ACCESSIBLE PORTION OF THE COUNTERTOP SHALL EXTEND |
| | THE SAME DEPTH AS THE SALES OR SERVICE COUNTERTOP. |
| | |
| | 3) SHEET A101 THE FLOOR PLAN SHOWS NEW WALL IN CORRIDOR |
| | 4 FEET WIDE. THERE IS NO ROOM FOR TURNING SPACES SEE |
| | 2020 FBC-ACCESSIBILITY CODE 304.3. |
| | |
| | 4) SHEET A101 THE FLOOR PLAN SHOWS AN EXISTING DOOR D-2 |
| | TO THE RESTROOM ONLY 2 FEET WIDE. FLORIDA ACCESSIBILITY |
| | CODE SECTION: DISPROPORTIONATE COST 202.4.1. PLEASE |
| | REVIEW HOW YOU ARE TO MEET DISPROPORTIONATE COST. |
| | EITHER THE CONTRACTOR OR THE DESIGNER OF RECORD ON |
| | THEIR LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO |
| | SPEND UP TO THE 20% ($1,000.00 DOLLARS) |
| | DISPROPORTIONATE FUNDS LISTED FOR EACH ELEMENT WHERE |
| | THE FUNDS ARE BEING SPENT AND IN THE ORDER LISTED IN |
| | SECTION 202.4.1 DISPROPORTIONATE COST OF THE 2020 |
| | ACCESSIBILITY CODE. THE INSTALLATION OF A NEW DOOR TO |
| | THE RESTROOM CAN BE ACCOMPLISHED FOR LESS THAN |
| | $1,000.00. FLORIDA ACCESSIBILITY CODE SECTION: |
| | DISPROPORTIONATE COST 202.4.1. PLEASE REVIEW HOW YOU |
| | ARE TO MEET DISPROPORTIONATE COST. EITHER THE |
| | CONTRACTOR OR THE DESIGNER OF RECORD ON THEIR |
| | LETTERHEAD NEED TO SHOW HOW THEY ARE GOING TO SPEND UP |
| | TO THE 20% DISPROPORTIONATE FUNDS LISTED FOR EACH |
| | ELEMENT WHERE THE FUNDS ARE BEING SPENT AND IN THE |
| | ORDER LISTED IN SECTION 202.4.1 DISPROPORTIONATE COST |
| | OF THE 2020 ACCESSIBILITY CODE. |
| | |
| | 5) THE FLOOR PLAN DOES NOT INDICATE IF AT THE FRONT |
| | ENTRY DOOR FLOOR IS THE SAME LEVEL AS THE EXTERIOR SLAB |
| | OR A DIFFERENCE IN ELEVATIONS. 202 FBC-ACCESS. CODE |
| | CHANGES IN LEVEL 303.2 AND 303.3. WHERE CHANGES IN |
| | LEVEL ARE PERMITTED IN THE FLOOR OR GROUND SURFACES, |
| | THEY SHALL COMPLY WITH SECTION 303. SEE 303.1 & 303.2. |
| | |
| | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| | REVIEW CYCLE. |
| | |
| | |
| | MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE |
| | WORKING FROM CITY HALL. |
| | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| | PART-TIME/ RETIRED. |
| | |
| | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| | BACK INTO THE OFFICE CALL |
| | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| | THANK YOU. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |