| Date |
Text |
| 2021-08-18 11:22:34 | BUILDING PLAN REVIEW |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/RPX306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | |
| | 1. VALUE |
| | |
| | NOTICE: AN ESTIMATE WAS PREPARED BY THIS REVIEWER. |
| | VALUE HAS BEEN ESTABLISHED AT $26,664.00. |
| | |
| | CITY OF WPB CHPT109.3 BUILDING PERMIT VALUATIONS. |
| | |
| | 1A. VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF WORK. |
| | 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE |
| | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED |
| | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, |
| | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE |
| | OF WORK. |
| | 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY |
| | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT |
| | RENTAL TO VERIFY VALUE. |
| | |
| | 2. BUILDING EGRESS IS BEING ALTERED. PROVIDE A LIFE |
| | SAFETY PLAN. |
| | |
| | 1003.6 MEANS OF EGRESS CONTINUITY. |
| | THE PATH OF EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL |
| | NOT BE INTERRUPTED BY A BUILDING ELEMENT OTHER THAN A |
| | MEANS OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER. |
| | OBSTRUCTIONS SHALL NOT BE PLACED IN THE MINIMUM WIDTH |
| | OR REQUIRED CAPACITY OF A MEANS OF EGRESS COMPONENT |
| | EXCEPT PROJECTIONS PERMITTED BY THIS CHAPTER. THE |
| | MINIMUM WIDTH OR REQUIRED CAPACITY OF A MEANS OF EGRESS |
| | SYSTEM SHALL NOT BE DIMINISHED ALONG THE PATH OF EGRESS |
| | TRAVEL. |
| | |
| | 1001.2MINIMUM REQUIREMENTS. |
| | IT SHALL BE UNLAWFUL TO ALTER A BUILDING OR STRUCTURE |
| | IN A MANNER THAT WILL REDUCE THE NUMBER OF EXITS OR THE |
| | MINIMUM WIDTH OR REQUIRED CAPACITY OF THE MEANS OF |
| | EGRESS TO LESS THAN REQUIRED BY THIS CODE. |
| | [F]1001.3MAINTENANCE. |
| | |
| | MEANS OF EGRESS SHALL BE MAINTAINED IN ACCORDANCE WITH |
| | THE FLORIDA FIRE PREVENTION CODE. |
| | [F]1001.4FIRE SAFETY AND EVACUATION PLANS. |
| | |
| | FIRE SAFETY AND EVACUATION PLANS SHALL BE PROVIDED FOR |
| | ALL OCCUPANCIES AND BUILDINGS WHERE REQUIRED BY THE |
| | FLORIDA FIRE PREVENTION CODE. SUCH FIRE SAFETY AND |
| | EVACUATION PLANS SHALL COMPLY WITH THE APPLICABLE |
| | PROVISIONS OF THE FLORIDA FIRE PREVENTION CODE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |