Plan Review Notes
Plan Review Notes For Permit 21080603
Permit Number 21080603
Review Stop B
Sequence Number 1
Notes
Date Text
2021-09-01 15:20:04WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21080603
 ADD: 1200 S. FLAGLER DR. # 506
 CONT: SBL CONTRACTING GROUP
 TEL: 561-676-6060
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 01/2021
 ACTION: DENIED
 1) FLOOR PLAN WITH CUT SECTION OF DROPPED CEILING.
 PLANS INDICATE TO USE RC-1 RESILIENT SOUND CHANNEL TO
 DROP THE CEILING APPROXIMATELY 7/8 OF AN INCH.
  
 1A) THE PLAN DOES NOT INDICATE HOW THE RC-1 CHANNEL IS
 GOING TO BE ATTACHED TO THE EXISTING CONCRETE CEILING
 AND THE FREQUENCY OF THE FASTENERS. 107.2.1.2.
 ADDITIONAL INFORMATION IS REQUIRED.
  
 1B) THE CUT SECTION FOR THE DROPPED CEILING SHOWS THE
 USE OF RC-1 RESILIENT SOUND CHANNEL (APPROXIMATELY 7/8
 INCH IN HEIGHT). WHAT TYPE OF HIGH HATS ARE GOING TO
 FIT IN THE SPACE CREATED BY THE HIGH HAT/ RC-1 CHANNEL?
 PLEASE SUPPLY A MANUFACTURERS SPEC FOR THIS PRODUCT.
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED. THE
 ELECTRICAL SHEET INDICATES 3 INCH LED HIGH HATS.
  
 1C) THE CUT SECTION FOR THE DROPPED CEILING SHOWS THE
 USE OF RC-1 RESILIENT SOUND CHANNEL AND NOTATION
 DRYWALL CEILING, THE THICKNESS OF THE DRYWALL IS NOT
 GIVEN? 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 1D) THE OVERALL HEIGHT OF THE DROPPED CEILING IS NOT
 GIVEN, WILL NEED TO SHOW COMPLIANCE WITH 2020 FBC-B
 SECTION 1208.2 MINIMUM CEILING HEIGHTS FOR HABITABLE
 ROOMS SHALL HAVE A CEILING NOT LESS THAN 7 FEET 6
 INCHES FROM FINISH FLOOR.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  