| 2021-09-22 11:13:37 | PLAN REVIEW BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | NOTICE: |
| | BASED ON THE OFFICIAL ZONING MAP REFERRED TO IN SECTION |
| | 53-2 OF CHAPTER 53 OF THE CITY CODE OF WEST PALM BEACH, |
| | FLORIDA, 1962, ADOPTED JUNE 15, 1964, YOUR PROPERTY, |
| | LOCATED AT 141 CORTEZ RD, W.P.B., FL, IS LOCATED IN AN |
| | AREA OF QUESTIONABLE SOILS AND REQUIRES INVESTIGATION |
| | BY A GEOTECHNICAL ENGINEER WITH ITS SUBSEQUENT SOILS |
| | REPORT AND DENSITY TESTING. |
| | |
| | 1. PROVIDE A SOILS REPORT |
| | GEOTECHNICAL INVESTIGATIONS |
| | FBC 1803.1 GENERAL. GEOTECHNICAL INVESTIGATIONS SHALL |
| | BE CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND |
| | REPORTED IN ACCORDANCE WITH SECTION 1803.6. |
| | R401.4 SOIL TESTS. |
| | WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL |
| | SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE, |
| | SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE |
| | LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL |
| | DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE |
| | THE SOIL?S CHARACTERISTICS AT A PARTICULAR LOCATION. |
| | THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN |
| | APPROVED METHOD. |
| | |
| | 2. PROVIDE A CURRENT COPY OF THE BOUNDRY LINE SURVEY. |
| | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| | 107.2.5. |
| | |
| | REF. PLAN PAGE A-0.1 FOR THE FOLLOWING: |
| | ENGINEERED FLOOD VENTS TO BE INSTALLED IN GARAGE WALLS. |
| | |
| | NOTICE: THIS PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD |
| | HAZARD AREA. NO BASE FLOOD ELEVATION REQUIRED. FLOOD |
| | VENTS ARE OPTIONAL. |
| | |
| | 3. PROVIDE THE ICC-ES REPORT OR STATE OF FLORIDA |
| | PRODUCT APPROVALS FOR THE PROPOSED SMART VENTS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 4. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY |
| | APPLIED FOAM INSULATION. DESIGNER SHALL SELECT SYSTEM |
| | TO BE INSTALLED. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | DEFERRALS PER DOR NOTE PG. A-0.0: |
| | WINDOWS AND EXT. DOORS |
| | SUBMIT PRODUCT APPROVALS FOR REVIEW AND APPROVAL PRIOR |
| | TO INSTALLATION. |
| | |
| | SEPERATE PERMIT REQUIRED FOR ROOFING. SEE DOR NOTE ON |
| | PG. A-0.0. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |
| | |
| | |
| | |