| 2022-02-28 18:14:15 | NEW SINGLE FAMILY RESIDENCE (R3) THIRD BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21071257 |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. |
| | |
| | |
| | 1- OK |
| | 2- OK |
| | 3- OK |
| | 4- OK. |
| | 5- OK. |
| | 6- OK. |
| | 7- OK. |
| | 8- OK. |
| | 9- OK. |
| | 10- OK. |
| | |
| | 11-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC |
| | 61G20-3.001 FOR |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW |
| | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL |
| | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL): |
| | |
| | ORIGINAL COMMENT: |
| | A)ENTRY DOOR OK W/ REVISED DESIGN PRESSURES. |
| | B)SLIDING GLASS DOORS. OK. |
| | C)SINGLE HUNG WINDOWS. OK. |
| | |
| | ORIGINAL COMMENT: |
| | D)METAL ROOF. AND, CLEARLY SPECIFY FASTENING METHOD. |
| | |
| | RESPONSE: |
| | RESPONSE LETTER (NOT BY THE ENGINEER OF RECORD) IS |
| | INCORRECT. TABLES ON PRODUCT APPROVAL ARE BASED ON THE |
| | DESIGN WIND SPEED FOR THE PROJECT LOCATION. THE DESIGN |
| | WIND SPEED FOR THIS PROJECT IS 170 MPH ULTIMATE. THESE |
| | ARE THE PARAMETERS TO USE THESE TABLES NOT THE NOMINAL |
| | WIND SPEED OF 132 MPH. THEREFORE, THE ORIGINAL COMMENT |
| | APPLIES. SEE BELOW. |
| | |
| | ACCORDING TO PRODUCT APPROVAL FL27985.06 THE FASTENING |
| | METHOD IS NOT RATED (NR) FOR ROOF ZONES 2 AND 3. A |
| | DESIGN PROFESSIONAL IS REQUIRED TO PROVIDE CALCULATIONS |
| | FOR FASTENING AT THESE ROOF ZONES. SEE FASTENING TABLES |
| | ON PAGE 3 OF METAL ROOFING INSTALLATION INSTRUCTIONS. |
| | PROVIDE SIGNED AND SEALED CALCULATIONS OR PROVIDE |
| | ANOTHER PRODUCT APPROVAL THAT MEETS THE DESIGN |
| | PRESSURES FOR ALL ROOF ZONES. |
| | |
| | E)WINDOW MULLIONS. OK. |
| | F)ROOFING UNDERLAYMENT OK. |
| | G)ALUMINUM SOFFIT OK. |
| | |
| | 12- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) REVISED METAL ROOF PRODUCT |
| | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |