Text |
| 2021-08-03 11:06:37 | OFFICE BUILDOUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) DRAWING C - 1 SHOWS THE DESIGN PER THE 2017 FBC - | | | PLEASE CORRECT - SHOULD BE PER THE 2020 FBC. | | | 2) DRAWING 1.0A - THE WALL LEGEND DOES NOT MATCH THE | | | FLOOR PLAN - SHOWS ALL WALLS THE SAME - NEW VERSES | | | EXISTING - PLEASE CLARIFY. | | | 3) DRAWING 1.0A - THE DOOR SCHEDULE IS MISSING DOOR | | | NUMBER 5. | | | 4) PLEASE SHOW THE ADJACENT UNIT OCCUPANCY | | | CLASSIFICATION - TO VERIFY OCCUPANCY SEPARATION PER FBC | | | 508.1 |
|