2021-10-19 13:44:43WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21071098
 ADD: 1781 PALM BEACH LAKES BLVD. SUITE W28
 CONT: OTHERS CONSTRUCTION CO.
 TEL: 561-262-4088
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. OCT. 19TH/ 2021
 ACTION: DENIED
  
 1) SEMI-COMPLIED. SUBMITTED THIS REVIEW SUPPLEMENT 002
 PROVIDING BUILDING J-10 WAS BUILT UNDER THE 2010
 FBC-BUILDING, AND ASCE 7-10. THE PLAN INDICATES THE
 PRODUCT APPROVAL TO BE FL 12882-R1 EXTERIOR SWING DOOR
 AND FL 14218-R3 STOREFRONT. PLEASE SUBMIT THESE PRODUCT
 APPROVALS AND TECHNICAL SHEETS IDENTIFYING THE OPENING
 WIDTH & HEIGHT, SILL HEIGTH, TYPE OF GLAZING, MULLION
 SIZE, LENGTH IF UNREINFORCED OR REINFORCED INFORMATION
 IF REQUIRED, ATTACHMENTS AND ASSOCIATE PRESSURES FOR
 EACH OPENING SIZE. 2020 FBC-B 1405.13.1 INSTALLATION.
 WINDOWS AND DOORS SHALL BE INSTALLED IN ACCORDANCE WITH
 APPROVED MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND
 SPACING SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND
 SHALL BE CALCULATED BASED ON MAXIMUM LOADS AND SPACING
 USED IN THE TESTS.
  
 PLEASE NOTE YOU MAY REQUEST A RECORDS RESEARCH REQUEST
 FOR THE APPROVED PRODUCT APPROVALS AND STOREFRONT SHOP
 DRAWINGS. THEY ARE FOUND UNDER REVISION 13080564.
 RECORD RESEARCH REQUEST GO TO MR. CRAIG MCPHERSON
 TELEPHONE NUMBER 561-805-6684. THERE MAYBE A FEE
 INVOLVED DEPENDING ON THE AMOUNT OF TIME IT TAKES TO
 RETRIEVE YOUR REQUEST.
  
 1ST ROUND OF COMMENTS. SHEET D-1 & A-8 DETAIL A
 INDICATES THE REMOVAL OF THE STOREFRONT DOORS AND A
 WINDOW, THEN RELOCATE IN A DIFFERENT LOCATION. TO REUSE
 THE STOREFRONT SYSTEM YOU MAY OBTAIN THE ORIGINAL
 PRODUCT APPROVALS WHEN THE GLAZING SYSTEM WAS INSTALLED
 OR YOU MAY HAVE AN ENGINEER CERTIFY THE INSTALLATION BY
 PROVIDING A RATIONAL ANALYSIS FOR THE ANCHORING SYSTEM
 AND ALSO DETERMINE IF THE INSTALLATION IS LARGE MISSILE
 IMPACT GLAZING. 104.11 ALTERNATE MATERIALS AND METHODS.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  