Plan Review Notes
Plan Review Notes For Permit 21071092
Permit Number 21071092
Review Stop B
Sequence Number 2
Notes
Date Text
2021-09-15 15:15:49OFFICE BUILDOUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) ACCESSIBLE RESTROOMS - THE GRAB BAR MAXIMUM HEIGHT
 SHOULD BE SHOWN TO THE TOP OF THE GRIPPING SURFACE (NOT
 THE CENTER OF THE GRAB BAR) FBC A 609.4 POSITION OF
 GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE,
  
 2) THE TOILET PAPER HOLDER LOCATION DIMENSIONS FROM THE
 FRONT OF THE TOILET SEAT IS SHOWN INCORRECTLY FOR AN
 ACCESSIBLE RESTROOM FBC A 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND
 SHALL NOT BE LOCATED BEHIND GRAB BARS.
  
 3) THE MIRROR DIMENSIONS FROM THE FLOOR SHOULD BE TO
 THE "REFLECTIVE SURFACE" FOR AN ACCESSIBLE RESTROOM PER
 FBC A603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 4) PLEASE SHOW ALL WOOD AND PLYWOOD BACKING TO BE FIRE
 RETARDANT PER FBC 603.1 AND FBC 803.13.2.1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved