| Date |
Text |
| 2021-09-15 15:15:49 | OFFICE BUILDOUT |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected]. |
| | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) ACCESSIBLE RESTROOMS - THE GRAB BAR MAXIMUM HEIGHT |
| | SHOULD BE SHOWN TO THE TOP OF THE GRIPPING SURFACE (NOT |
| | THE CENTER OF THE GRAB BAR) FBC A 609.4 POSITION OF |
| | GRAB BARS. |
| | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| | THE GRIPPING SURFACE, |
| | |
| | 2) THE TOILET PAPER HOLDER LOCATION DIMENSIONS FROM THE |
| | FRONT OF THE TOILET SEAT IS SHOWN INCORRECTLY FOR AN |
| | ACCESSIBLE RESTROOM FBC A 604.7 DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| | SHALL NOT BE LOCATED BEHIND GRAB BARS. |
| | |
| | 3) THE MIRROR DIMENSIONS FROM THE FLOOR SHOULD BE TO |
| | THE "REFLECTIVE SURFACE" FOR AN ACCESSIBLE RESTROOM PER |
| | FBC A603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 4) PLEASE SHOW ALL WOOD AND PLYWOOD BACKING TO BE FIRE |
| | RETARDANT PER FBC 603.1 AND FBC 803.13.2.1 |