| Date |
Text |
| 2021-09-23 14:36:28 | 21070936 255 EVERNIA ST 310 |
| | |
| | PLUMBING COMMENTS: APPROVED |
| | |
| | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD |
| | INSPECTOR'S APPROVAL |
| | |
| | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE |
| | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN |
| | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM |
| | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND |
| | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF |
| | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY |
| | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM |
| | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES |
| | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO |
| | AVOID VOIDING OF THE PERMIT. |
| | |
| | SHALL COMPLY WITH REQUIREMENTS OF THE FAIR HOUSING |
| | DESIGN MANUAL CHAPTER 7 |
| | |
| | PROVISO: PER FBC PL 421.5.2.4, SHEET COPPER PAN SHALL |
| | CONFORM TO ASTM B152 AND SHALL WEIGH NOT LESS THAN 12 |
| | OUNCES PER SQUARE FOOT. THE COPPER SHEET SHALL BE |
| | INSULATED FROM CONDUCTING SUBSTANCES OTHER THAN THE |
| | CONNECTING DRAIN BY 15 POUND ASPHAULT FELT OR THE |
| | EQUIVALENT. SHEET COPPER SHALL BE JOINED BY SOLDERING |
| | OR BRAZING |
| | |
| | PROVISO: PRE-SLOPED BASE FOR SHOWER LINER SHALL HAVE A |
| | PITCH OF 1/4 INCH PER FOOT SLOPED TO DRAIN PER FBC PL |
| | 421.5.2. |
| | |
| | PLEASE NOTE THAT WHEN SCANNED DRAWINGS ARE SUBMITTED |
| | WITH CONTRACTOR'S PRINTED NAME, SIGNATURE AND LICENSE |
| | NUMBER IN ACCORDANCE WITH WPB FBC 107.3.4.2, A PAPER |
| | PLAN WITH WET SIGNATURE SHALL BE PROVIDED TO THE |
| | BUILDING DEPARTMENT FOR HARD RECORD FILE PRIOR TO |
| | ISSUANCE OF A PERMIT. |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | MOBILE 561-246-0882 |
| | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND |
| | THURSDAYS |
| | |
| | 21070936 255 EVERNIA ST 310 |