Plan Review Notes
Plan Review Notes For Permit 21070763
Permit Number 21070763
Review Stop Z
Sequence Number 2
Notes
Date Text
2021-12-13 15:24:26ZONING REVIEW #1 9/15/21 COMMENTS:
  
 1. PLEASE PROVIDE A CURRENT SURVEY OF THE PROPERTY.
 [SATISFIED]
  
  
 2. PLEASE ADDRESS ERRORS OR INCONSISTENCIES BETWEEN
 SUBMITTED DRAWINGS AND DIMENSIONS/CALCULATIONS ON
 PLANS. [PARTIALLY SATISFIED]
 - SITE PLAN IS LABELED 813 6TH STREET. [SATISFIED]
 - SITE PLAN SHOWS SITE AREA AS 6,725 SF, LANDSCAPE PLAN
 SHOWS 6,250 SF. [SATISFIED]
 - SITE PLAN STATES LANDSCAPE AREA OF 4,821 SF,
 LANDSCAPE PLAN SHOWS LANDSCAPE AREA OF 4,244 SF.
 [SATISFIED]
 - SITE PLAN IMPERVIOUS 4,821 SF (71.7 PERCENT)
 LANDSCAPE PLAN IMPERVIOUS 4,244 SF (67.9 PERCENT).
 [SATISFIED]
 - SITE PLAN PERVIOUS 2,006 SF (29.8 PERCENT) LANDSCAPE
 PLAN PERVIOUS 2,006 SF (32 PERCENT). [SATISFIED]
 - DOUBLE CHECK THE NUMBER AND TYPE OF PLANTS LISTED IN
 THE LANDSCAPE PLAN CHART, NUMBER/TYPE DOESNT APPEAR TO
 BE CONSISTENT TO DRAWINGS. [SATISFIED]
 - DRAWING SHOWS TREE IN CENTER OF DRIVEWAY. [SATISFIED]
 - CLARIFY IMPERVIOUS/PERVIOUS, ARE THE VALUES OR LABELS
 SWITCHED? (I.E. LANDSCAPE AREA VALUES SAME AS
 IMPERVIOUS) [PARTIALLY SATISFIED]
 [PARTIALLY SATISFIED] DOUBLE CHECK/CORRECT THE TEXT ON
 THE PLANS. CONFUSION WITH "PERVIOUS" VS. "IMPERVIOUS".
 PERCENTAGES AND VALUES SHOULD BE SWAPPED WITH THE
 LABELS? WILL NEED A TREE DISPOSITION OR ALTERATION
 PERMIT WHEN REMOVING TREES OR PALMS. SUBMIT FOR
 SEPARATE LANDSCAPE PERMIT, IRRIGATION PERMIT, ETC. AS
 IS NECESSARY.
  
  
 3. PLEASE ADJUST FRONT SETBACK FROM THE 15 FT. MINIMUM
 SHOWN AND THE 17 FT. 11 IN. SETBACK FOR THE BUILDING TO
 BE IN COMPLIANCE WITH THE REQUIRED CONTEXTUAL SETBACK.
 THE NEW CONTEXTUAL MINIMUM/BUILDING SETBACK SHALL BE 20
 FT.
 [SATISFIED]
  
  
 4. PLEASE ADJUST THE DRIVEWAY AND FRONT YARD TO BE IN
 COMPLIANCE WITH LANDSCAPE STANDARDS. STANDARDS REQUIRE
 THAT 75 PERCENT OF THE FRONT YARD AREA SHALL BE
 LANDSCAPED WITH LIVING PLANT MATERIAL, AS IT IS SHOWN
 THE DRIVEWAY AND WALKWAY (IMPERMEABLE SURFACES OF FRONT
 YARD) EXCEED THE 25 PERCENT ALLOWED. [NOT SATISFIED]
 - PLEASE NOTE, NEW CALCULATION FOR FRONT YARD WILL BE
 BASED FROM THE NEW CONTEXTUAL SETBACK OF 20 FT.
 - DRIVEWAY AND WALKWAY WILL HAVE TO BE NARROWED,
 POTENTIAL ALTERNATIVE OF RIBBON DRIVE.
 [NOT SATISFIED] FRONT YARD = 20' (SETBACK) X 50'
 (PROPERTY WIDTH) = 1000 SF. THEREFORE 750 SF NEEDS TO
 BE LANDSCAPE. DRIVEWAY PORTION 18'X20'=360 SF, EXCEEDS
 THE 25% OF FRONT LAWN AS IMPERVIOUS, NOT INCLUDING THE
 ADDITIONAL % FROM THE WALKWAY AND DRIVEWAY ENTRANCE,
 (REPEAT COMMENT) DRIVEWAY AND WALKWAY WILL HAVE TO BE
 NARROWED, EXPLORE POTENTIAL ALTERNATIVE OF RIBBON
 DRIVE.
  
  
  
  
 ANY QUESTIONS OR CONCERNS CAN BE DIRECTED TO CHRIS
 KIMMERLY OR ANA MARIA APONTE AT: [email protected] OR
 [email protected] ALSO AT 822-1426 OR 822-1439.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved