| Plan Review Notes For Permit 21070759 |
| Permit Number |
21070759 |
|
| Review Stop |
Z |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-09-15 10:06:49 | | | | 1. PLEASE PROVIDE A CURRENT SURVEY OF THE PROPERTY. | | | | | | 2. PLEASE ADDRESS ERRORS OR INCONSISTENCIES BETWEEN | | | SUBMITTED DRAWINGS AND DIMENSIONS/CALCULATIONS ON | | | PLANS. | | | | | | | | | - DOUBLE CHECK THE NUMBER AND TYPE OF PLANTS LISTED IN | | | THE LANDSCAPE PLAN CHART, NUMBER/TYPE DOESN?T APPEAR TO | | | BE CONSISTENT TO DRAWINGS. | | | | | | - LANDSCAPE PLAN SHOWS TREE IN MIDDLE OF HOUSE AND | | | DRIVEWAY? | | | | | | - CLARIFY IMPERVIOUS/PERVIOUS, ARE THE VALUES OR LABELS | | | SWITCHED? (I.E. LANDSCAPE AREA VALUES SAME AS | | | IMPERVIOUS) | | | | | | | | | 3. PLEASE ADJUST FRONT SETBACK FROM THE 15 FT. MINIMUM | | | SHOWN AND THE 17 FT. 11 IN. SETBACK FOR THE BUILDING TO | | | BE IN COMPLIANCE WITH THE REQUIRED CONTEXTUAL SETBACK. | | | THE NEW CONTEXTUAL MINIMUM/BUILDING SETBACK SHALL BE 20 | | | FT. | | | | | | 4. PLEASE ADJUST THE DRIVEWAY AND FRONT YARD TO BE IN | | | COMPLIANCE WITH LANDSCAPE STANDARDS. STANDARDS REQUIRE | | | THAT 75 PERCENT OF THE FRONT YARD AREA SHALL BE | | | LANDSCAPED WITH LIVING PLANT MATERIAL, AS IT IS SHOWN | | | THE DRIVEWAY AND WALKWAY (IMPERMEABLE SURFACES OF FRONT | | | YARD) EXCEED THE 25 PERCENT ALLOWED. | | | | | | - PLEASE NOTE, NEW CALCULATION FOR FRONT YARD WILL BE | | | BASED FROM THE NEW CONTEXTUAL SETBACK OF 20 FT. | | | | | | - DRIVEWAY AND WALKWAY WILL HAVE TO BE NARROWED, | | | POTENTIAL ALTERNATIVE OF RIBBON DRIVE. | | | |
|