 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected] AND REQUEST
 THAT IT BE CONVERTED TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R8 SELECTED OPTION FOR SYSTEM NO W-4;
 EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (15 < H
 < 20); ULTIMATE WIND SPEED (180). ZONE 3 IS MARKED
 ?N/A? WHICH INDICATES SYSTEM CANNOT BE USED WITHIN THE
 PRESSURE ZONE. THE CORRECT ULTIMATE DESIGN WIND SPEED
 FOR THE LISTED ADDRESS IS (170). PLEASE SELECT THE
 CORRECT OPTIONS.
 2. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF
 DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW
 ROOFING CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF
 SLOPE(S), ROOF HEIGHT(S).
  