Plan Review Notes
Plan Review Notes For Permit 21070505
Permit Number 21070505
Review Stop B
Sequence Number 1
Notes
Date Text
2021-09-02 08:30:34BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC RESIDENTIAL WITH WPB
 CHAPTER 1 AMENDMENTS
  
 CORRECTIONS NEEDED -
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) PRODUCT APPROVALS THAT ARE
 LISTED ON THE DRAWINGS.
 2) EXTERIOR WALL (EWS02) - PLEASE PROVIDE EFIS
 ATTACHMENT DETAILS - PLEASE SHOW THE STRUCTURAL BACKING
 FOR THE EFIS IF REQUIRED FBC 1408.3 STRUCTURAL DESIGN.
 THE UNDERLYING STRUCTURAL FRAMING AND SUBSTRATE SHALL
 BE DESIGNED AND CONSTRUCTED TO RESIST LOADS AS REQUIRED
 BY CHAPTER 16.
  