| 2021-07-16 08:28:46 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) ENERGY CALCS. HAVE BEEN REVISED - YOU WILL NEED TO | | | REVISE THE DRAWINGS TO SHOW THE CORRECT INSULATION TO | | | MATCH THE ENERGY CALCS. | | | 2) ENERGY CALCS. SHOW R30 IN THE CEILING - R30 BAT | | | INSULATION IN A 2 X 10 RAFTER WILL NOT ALLOW FOR THE | | | REQUIRED 1 INCH VENTILATION GAP PER FBC R 806.3 VENT | | | AND INSULATION CLEARANCE. | | | WHERE EAVE OR CORNICE VENTS ARE INSTALLED, BLOCKING, | | | BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW | | | OF AIR. NOT LESS THAN A 1-INCH (25 MM) SPACE SHALL BE | | | PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING | | | AND AT THE LOCATION OF THE VENT. | | | |
|