| 2021-09-16 10:25:19 | 3RD ROOFING REVIEW: THE COMMENTS FROM THE 2ND REVIEW ON | | | 8/27/21 COPIED BELOW WERE NOT ADDRESSED. PLEASE COMPLY, | | | | | | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE CIRCLE THE UNDERLAYMENT SYSTEM TO BE USED ON | | | PRODUCT APPROVAL FL5259 - R33 - SEE SECTION 5.8 ON THE | | | PRODUCT APPROVAL. FBC WPB 107.2.1.1 | | | 2) PLEASE PROVIDE BUILDING HEIGHT AND ROOF SLOPE | | | INFORMATION FBC WPB 107.2.1.1 | | | |
|