Plan Review Notes
Plan Review Notes For Permit 21070252
Permit Number 21070252
Review Stop B
Sequence Number 2
Notes
Date Text
2021-08-24 08:14:37WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT:21070252
 ADD: 529 S. FLAGLER DR. # 29E
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: TUES. AUGUST 24, 2021
 ACTION: DENIED
 1) SHEET S-1, SITE PLAN BY COVENANT ENGINEERING, INC. /
 EDWARD J. KRANZ PE:
  
 1A-C) COMPLIED.
  
 1D)(1) THE DESIGNER OF RECORD INDICATES OPENING A IN
 WALL ZONE 5 WITH + 55.0/ -72.8 PRESSURES. PLEASE NOTE
 THE PRODUCT APPROVAL FL 19092.1 SHOWS PRESSURES FOR
 EACH DOOR PANEL AND INTERLOCKING DOOR FRAME MEMBER,
 SHEET 7/ 18 IS HIGHLIGHTED PANEL WIDTH & HEIGHT OF 52X
 102 WITH PRESSURES OF +110.6 AND -129.2 FOR GLASS TYPE
 A & A1. PLEASE REVIEW YOUR STATED PRESSURES EVEN WITH
 THE WIND BREAK SHOWN IN THE WALL ZONE 5 THERE WOULD BE
 A GREATER VORTEX CREATED IN THIS CASE. STATED PRESSURES
 AT 300 FT. D EXPOSURE FOR 37 SQ. FT. (PANEL) ARE
 APPROX. +66.8/ -119. 0 PSF/ VASD. PLEASE UPDATE PLANS.
  
 1D)(2) PLEASE NOTE THE PRODUCT APPROVAL FL 19092.1
 SHEET 4 OF 12 SHIM AND ANCHOR NOT HIGHLIGHTED.
  
 1D)(3) FL. 18411.1 FIXED GLASS. THE DESIGNER OF RECORD
 NEEDS TO REVIEW THE POSITIVE AND NEGATIVE PRESSURES
 GIVEN ON SHEET SP-1 FOR OPENINGS 2 & 3, THEY ARE LOW
 FOR EXPOSURE D AT 300 FT ABOVE GRADE. FOR 40 SQ. FT.
 THEY SHOULD BE CLOSER TO +66.1/ -114.0 PSF/ VASD, TAKEN
 FROM FRANK BENNARDO/ ENGINEERING EXPRESS ENGINEERING
 SHEETS FOR 290 FT. MEAN ROOF HEIGHT.
  
 1E) COMPLIED.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL
 MY WORK HOURS ARE MON. & TUES. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved