2021-07-20 10:34:22WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT:21070252
 ADD: 529 S. FLAGLER DR. # 29E
 CONT: TBD/ TO BE DETERMINED
 TEL:
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JULY 19TH/ 2021
 ACTION: DENIED
 1) SHEET S-1, SITE PLAN BY COVENANT ENGINEERING, INC. /
 EDWARD J. KRANZ PE:
 1A) THE SITE PLAN IS LOCKED AND CAN NOT CHECK
 ELECTRONIC SIGNATURE. 61G15-23.005 PROCEDURES FOR
 SIGNING AND SEALING ELECTRONICALLY TRANSMITTED PLANS
 (DIGITAL SIGNATURES), SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS.
  
 1B) THE SITE PLAN INDICATES THE LOCATION IS IN FT.
 LAUDERDALE FL. WRONG MUNICIPALITY. WEST PALM BEACH, FL.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED.
  
 1C) THE EXPOSURE CATEGORY IS LISTED AS C. PLEASE REVIEW
 SECTION 1609.4.3 EXPOSURE CATEGORIES FOR D. IF S RAY IS
 SHOOT OUT OVER THE WATER AND TRAVELS 5000 FT OVER
 WATER, AND THE SAME RAY DOES NOT TRAVEL OVER LAND MORE
 THAN 600 FT, THE LOCATION IS TO BE CONSIDERED AN D
 EXPOSURE. THAT BEING SAID, THERE ARE 2 BUILDINGS ON
 THIS SITE AND THE LOCATION WHERE THE GLAZING IS TO BE
 INSTALLED DOES NOT INDICATE WHICH BUILDING AND THE
 RELATIONSHIP TO THE INTERCOSTAL WATERWAY. THAT WILL BE
 THE FINAL DETERMINATION IF THIS IS A C OR D EXPOSURE.
 IN THE PAST THIS BUILDING HAS ALWAYS BEEN CONSIDERED A
 D EXPOSURE.
  
 1D) THE DESIGNER OF RECORD HAS GIVEN PRESURES FOR
 OPENINGS A, B, & C. INCORPORATED IN THE FLOOR PLAN
 THERE IS A SCHEDULE FOR THESE 3 OPENINGS WITH PRESURES
 FOR ZONE 4 AND ZONE 5. THE DESIGNER OF RECORD HAS NOT
 HIGHLIGHTED OR SHOWN WHICH PREURES ARE RELEVANT TO THIS
 PROJECT, HE LEAVES IT UP TO THE CONTRACTOR. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 1E) THE DESIGNER OF RECORD IN THE WIND DESIGN HAS LEFT
 OUT IF THE PREURES GIVEN ARE FOR INTERNAL PRESSURE
 COEFFICIENT. NOTE OPENINGS 1 & 2 ARE FOR OPENINGS IN
 WALLS WHERE OPENING 3 IS OUT IN THE OPEN NOT IN A
 ENCLOSED ENVIROMENT. 1603.1.4 WIND DESIGN DATA. UNTIL
 THESE ISSUES CAN BE CLEARED UP THE PRODUCT APPROVALS
 CAN NOT BE REVIEWED.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
 WORKING HOURS ARE MON.- WED. 8:00 AM- NOON. PART-TIME/
 RETIRED.
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL
 MY WORK HOURS ARE MON. & TUES. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved