| 2022-01-20 09:03:01 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 2ND REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLEASE REMOVE NOTE ON SITE PLAN, SP-1 THAT STATES | | | "ALL EQUIPMENTS MOUNTED ABOVE B.F.E" | | | THIS PROPERTY IS NOT LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA AND DOES NOT HAVE A BASE FLOOF ELEVATION. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. REF. PLAN PAGE S1.1, ROOF SHEATHING FASTENER DIAGRAM | | | AND FASTENER SCHEDULE FOR THE FOLLOWING COMMENT: | | | ROOF ZONES SHALL BE IDENTIFIED AS ZONES 1, 2E, 2R & 3 | | | PER FBC R301.2. (7). | | | FASTENERS SHALL BE BASED ON THE DESIGN PRESSURE OF EACH | | | ZONE. | | | R301.2.1.1WIND DESIGN REQUIRED. | | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|