| Date |
Text |
| 2021-10-14 12:25:12 | 3RD REVIEW FBC-2020 PLUMBING |
| | PERMIT- 21070167 |
| | 10/13/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIE. |
| | |
| | 1) SHEET GN100: THE REVISED PLAN SHEET NOW ESTABLISHES |
| | THE BASIS OF DESIGN FOR THE ACCESSIBLE DWELLING UNITS |
| | IS THE 2009 ICC/ANSI A117 ACCESSIBLE AND USABLE |
| | BUILDINGS AND FACILITIES STANDARD. TYPE A UNITS ARE |
| | SPECIFIED. PLEASE REVIEW SHEETS GN102, GN103, A805 & |
| | A806 AND PROVIDE THE FOLLOWING MISSSING DETAILS PER THE |
| | STANDARD: |
| | |
| | A) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED |
| | FLOORS- SECTION 1003.11.7.4. |
| | B) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB |
| | BARS FOR THE WATER CLOSETS- SECTIONS & FIGS. 604.5.1, |
| | 604.5.2. PLEASE CORRECT REAR GRAB BARS ON SHEETS GN102 |
| | & GN103 AND PROVIDE COMPLETE DETAILS ON SHEETS A805 & |
| | A806. |
| | C) HEIGHTS OF THE LAVATORY SINK RIM OR COUNTER SURFACE |
| | FROM THE FINISHED FLOOR- SECTIONS 1003.11.5 & 606.3. |
| | D) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO |
| | THE REFLECTIVE SURFACES- SECTION 1003.11.6. THE DETAIL |
| | DOES NOT INDICATE REFLECTIVE SURFACE. |
| | E) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS ? |
| | SECTION 1003.11.7.5. |
| | F) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED |
| | FROM THE FRONTS OF THE WATER CLOSETS- SECTION AND |
| | FIGURE 604.10.7. |
| | G) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTIONS |
| | 606.2, 306.2, 306.3 AND FIG. 306.3 |
| | H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB |
| | BARS FOR THE ACCESSIBLE SHOWER- SECTION & FIG. 608.3.2. |
| | TO HELP EXPEDITE REVIEW AND INSPECTION OF THE GRAB |
| | BARS, PLEASE PROVIDE CONSISTENT LENGTH AND SPACING |
| | MEASUREMENTS ON THE PLANS AND INDICATE THE HEIGHT |
| | MEASUREMENTS ARE TO THE TOPS OF THE GRIPPING SURFACES. |
| | I) LOCATION OF CONTROL, FAUCET, AND SHOWER SPRAY IN THE |
| | SHOWER- SECTION AND FIG. 608.5.2. THE ELEVATION |
| | DRAWINGS SHOW ONE CONTROL VALVE ABOVE THE 48-INCH |
| | MAXIMUM HEIGHT. |
| | |
| | 2) GN100, A102: THE PLANS INDICATE HVI UNITS WILL BE |
| | INSTALLED ON THE 2ND-5TH FLOORS. PLEASE INDICATE WHICH |
| | CODE OR STANDARD IS THE BASIS OF DESIGN FOR THESE UNITS |
| | AND PROVIDE COMPLIANCE DRAWINGS AND DETAILS- SECTION |
| | 107.2.1 WPB. |
| | |
| | 3) D101B, D201.B: THE SHEETS ARE IN CONFLICT REGARDING |
| | THE TOILET COMPARTMENTS. IT APPEARS D201B NEEDS TO BE |
| | CORRECTED. |
| | |
| | 4) SHEETS A102, A103, A104, A105: TO HELP EXPEDITE PLAN |
| | REVIEW, CONSTRUCTION, AND INSPECTION OF THE RENOVATED |
| | DWELLING UNITS, PLEASE PROVIDE REFERENCE NOTES OR |
| | TARGETS INDICATING ON WHICH SHEETS THE ENLARGED FLOOR |
| | PLANS ARE LOCATED- SECTION 107.2.1 WPB. |
| | |
| | 5) SHEETS A101A & A814: THE KNEE AND TOE CLEARANCES FOR |
| | THE LOUNGE SINK SHALL BE IN COMPLIANCE WITH SECTIONS |
| | 606.2, 306.2, & 306.3 FBC ACC. |
| | |
| | 6) A101, A101B, A825: MISSING ACCESSIBILITY DETAIL PER |
| | THE FBC ACC: |
| | |
| | A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | LAVATORIES- SECTION 606.2. |
| | B) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE |
| | WALLS- SECTION 604.2. |
| | C) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED |
| | FLOORS- SECTION 604.4. |
| | D) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB |
| | BARS FOR THE WATER CLOSETS- SECTION 604.5 & 609.4, |
| | FIGURES 604.5.1 & 604.5.2. |
| | E) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION |
| | 606.2, 306.2, & 306.3 FBC ACC. |
| | F) HEIGHT AND DEPTH OF THE URINAL- SECTION 605.2. |
| | G) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| | URINAL- SECTION 605.3 |
| | H) PLEASE PROVIDE THE DIMENSIONS OF THE EXISTING TOILET |
| | COMPARTMENTS TO VERIFY COMPLIANCE WITH SECTION 604.8.1. |
| | I) PLEASE NOTE THAT ACCESSIBLE TOILET COMPARTMENT DOORS |
| | SHALL NOT SWING INTO THE MINIMUM REQUIRED COMPARTMENT |
| | AREA, DOORS SHALL BE SELF-CLOSING, AND PULLS PROVIDED |
| | ON BOTH SIDES- 604.8.1.2. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | |