Plan Review Notes
Plan Review Notes For Permit 21070167
Permit Number 21070167
Review Stop P
Sequence Number 2
Notes
Date Text
2021-09-23 13:03:072ND REVIEW FBC-2020 PLUMBING
 PERMIT- 21070167
 9/23/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES FOR
 FURTHER CLARIFICATION.
  
 2) FAILED. GN100: PLEASE PROVIDE A LIST OF DWELLING
 UNITS, THE UNIT FLOOR LEVELS, AND COMMON AREAS THAT
 WILL BE ALTERED AND IMPROVED IN ACCORDANCE WITH THE
 CHOSEN ACCESSIBILITY STANDARD. INDICATE WHICH
 ADMINISTRATIVE AUTHORITY HAS DETERMINED THE TYPE A
 DESIGN TO BE USED AND THE NUMBER OF DWELLING UNITS TO
 BE REMODELED. PLEASE CLARIFY HOW THE 5% NUMBER OF UNITS
 TO BE CONVERTED TO TYPE A WAS DETERMINED-UNDER WHICH
 ADMISINSTRATIVE AUTHORITY- SECTION 201 2009 ICC/ANSI
 A117.
  
 4) FAILED. GN102 & A805- 2009 ICC/ANSI A117: THE
 REVISED SHEET INDICATES ADA TYPE 5 DESIGN. FOR
 CLARIFICATION PLEASE INDICATE TYPE A OR B, 1BEDROOM OR
 EFFICIENCY FOR ALL FLOOR PLAN DRAWINGS A802- A806.
 PLEASE NOTE THERE IS NO CORRELATIING SCHEDULE FOR
 NUMBERED TYPE UNITS 2-6- SECTION 107.2.1 WPB.
  
 E) FAILED. THE CONTROLS AND HAND SHOWER SHALL BE
 LOCATED ON THE BACK WALL OF THE SHOWER ABOVE THE GRAB
 BAR, 48 INCHES MAXIMUM ABOVE THE SHOWER FLOOR AND 16
 INCHES MINIMUM AND 27 INCHES MAXIMUM FROM THE END WALL
 BEHIND THE SET- SECTION AND FIGURE 608.4.2. THE
 ELEVATION 5 DETAIL ON A805 SHOWS CONTROLS AT (5FT.
 10-5/8-INCHES) HOWEVER MAXIMUM ALLOWED IS 48 INCHES.
  
 F) FAILED. THE HORIZONTAL GRAB BARS SHALL BE INSTALLED
 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE
 FINISHED BATHROOM FLOOR AND SHOWER FLOOR TO THE TOPS OF
 THE GRIPPING SURFACES- 609.4. DETAILS 5 & 6 ON A805-
 THE MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB
 BARS.
  
 H) FAILED. PROVIDE DETAILS FOR THE KITCHEN SINK REMOVAL
 CABINET INDICATING COMPLIANCE WITH SECTION 1003.12.4.1
 ITEMS 1 & 2 (A, B, & C). SHEET GN101: SEE FIGURES
 C606.2(A), C306.1(B), & C306.1 (C) AND CORRECT DETAIL
 20 TO THE MIN. 17 INCH AND MAX 25-INCH KNEE AND TOE
 CLEARANCE DIMENSIONS. PLEASE PLACE THE DIMENSIONS IN
 THE CORRECT LOCATION BELOW THE SINK.
  
 NEW COMMENT: INDICATE THE HEIGHTS OF THE MIRROR ARE
 FROM THE FINISHED FLOORS TO THE REFLECTIVE SURFACE-
 SECTION 603.3.
  
 5) FAILED. GN103 & A806: 2009 ICC/ANSI A117: THE
 REVISED SHEET INDICATES ADA TYPE 6 DESIGN. FOR
 CLARIFICATION PLEASE INDICATE TYPE A OR B, 1BEDROOM OR
 EFFICIENCY FOR ALL FLOOR PLAN DRAWINGS A802- A806.
 PLEASE NOTE THERE IS NO CORRELATIING SCHEDULE FOR
 NUMBERED TYPE UNITS 2-6- SECTION 107.2.1 WPB.
  
 E) FAILED. THE CONTROLS AND HAND SHOWER SHALL BE
 LOCATED ON THE BACK WALL OF THE SHOWER ABOVE THE GRAB
 BAR, 48 INCHES MAXIMUM ABOVE THE SHOWER FLOOR AND 16
 INCHES MINIMUM AND 27 INCHES MAXIMUM FROM THE END WALL
 BEHIND THE SET- SECTION AND FIGURE 608.4.2. THE
 ELEVATION 5 DETAIL ON A806 SHOWS CONTROLS AT (5FT.
 10-5/8-INCHES) HOWEVER MAXIMUM ALLOWED IS 48 INCHES
  
 F) FAILED. THE HORIZONTAL GRAB BARS SHALL BE INSTALLED
 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE THE
 FINISHED BATHROOM FLOOR AND SHOWER FLOOR TO THE TOPS OF
 THE GRIPPING SURFACES- 609.4. DETAILS 5 & 6 ON A806-
 THE MEASUREMENT IS SHOWN TO THE CENTER OF THE GRAB
 BARS.
  
 H) FAILED. PROVIDE DETAILS FOR THE KITCHEN SINK REMOVAL
 CABINET INDICATING COMPLIANCE WITH SECTION 1003.12.4.1
 ITEMS 1 & 2 (A, B, & C). SHEET GN101: SEE FIGURES
 C606.2(A), C306.1(B), & C306.1 (C) AND CORRECT DETAIL
 20 TO THE MIN. 17 INCH AND MAX 25-INCH KNEE AND TOE
 CLEARANCE DIMENSIONS. PLEASE PLACE THE DIMENSIONS IN
 THE CORRECT LOCATION BELOW THE SINK. PLEASE NOTE THE
 ARCHIITECT?S RESPONSE TO THIS COMMENTS REFERS TO SHEETS
 A902 & A903 WHICH HAVE NOT INCLUDED IN THE PLAN SETS.
  
 NEW COMMENT: INDICATE THE HEIGHTS OF THE MIRROR ARE
 FROM THE FINISHED FLOORS TO THE REFLECTIVE SURFACE-
 SECTION 603.3.
  
 7) FAILED. A101.B: PROVIDE ENLARGED MEN'S AND WOMEN'S
 BATHROOM DRAWINGS INDICATING PLUMBING FIXTURE
 INSTALLATION COMPLIANCE WITH THE FBC ACCESSIBILITY
 CODE- 2020. BASED ON THE PLANS IT APPEARS THESE
 BATHROOMS ARE FOR BOTH PRIVATE AND PUBLIC USE. PLEASE
 SEE SECTION 213.3 AND PROVIDE DRAWINGS AND DETAILS IN
 COMPLIANCE WITH THE FBC ACC. PLEASE ADD CODE DATA TO
 SHEET A101, A101A, A1018- FBC ACCESSIBILITY- 2020 7TH
 EDITION. THE PLANS ARE INDICATING NON-COMPLIANCE FOR
 THE MEN'S AND WOMEN'S TOILET COMPARTMENTS WHICH ARE
 EACH REQUIRED TO CONTAIN AN ACCESSIBLE LAVATORY-
 SECTION 213.3.1, 604.8.1, & 604.8.6 FBC ACC. THE PLANS
 SHOW DEMOLITION OF THE EXISTING COMPARTMENTS WHICH
 INDICATES NEW CONSTRUCTION COMPARTMENTS CAN BE
 CONSTRUCTED AT THIS TIME TO MEET THE CODE. PLEASE REFER
 TO SECTION 202.3 FBC ACC FOR ADDITIONAL ADVISORY
 INFORMATION. PLEASE ALSO PROVIDE PLUMBING FIXTURE
 CALCULATIONS FOR THE GROUND FLOOR BASED ON TABLE 403.1
 FBC P. PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED
 AND PROVIDED NUMBER OF FIXTURES.
  
 A) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 THE WATER CLOSETS- SECTION 604.3. PENDING PLAN
 CORRECTIONS.
  
 B) FAILED. CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR
 THE LAVATORIES- SECTION 606.2. PENDING PLAN
 CORRECTIONS.
  
 C) FAILED. TURNING SPACE DIAMETERS- SECTION 304.3.
 SHEET A825- NOT PROVIDED IN COMPARTMENTS.
  
 D) FAILED. CENTERLINES OF THE WATER CLOSETS FROM THE
 SIDE WALLS- SECTION 604.2. SHEET A825- NOT PROVIDED.
  
 E) NEW COMMENT- REFER TO SECTION 604.8.1.2 FBC ACC AND
 VERIFY THE TOILET COMPARTMENT DOORS WILL BE SELF
 CLOSING.
  
 F) NEW COMMENT- THE DOOR FOR THE MEN?S TOILET
 COMPARTMENT SHALL NOT SWING INTO THE CLEAR FLOOR SPACE
 REQUIRED FOR THE ACCESSIBLE URINAL- SECTION 603.2.3 FBC
 ACC.
  
 12) FAILED. P301: PROVIDE UL TESTED AND APPROVED
 FIRESTOPPING ASSEMBLY DETAILS FOR PIPE PENETRATIONS ON
 THE PLAN- SECTION 315.1 FBC P AND SECTION 714.4.1.2 FBC
 B. THE DETAIL PROVIDED DOES NOT MEET COMPLIANCE. THE
 DETAIL IS NOT A UL ASSEMBLY. THE ASSEMBLY MAY BE
 DEFERRED AND INCLUDED IN A LIST OF DEFERRED SUBMITTALS
 ON THE PLAN- SECTION 107.3.4.1 WPB.
  
 13) FAILED. P401: PROVIDE CAST IRON PIPE AND FITTING
 SPECIFICATIONS IN COMPLIANCE WITH SECTION 303.5 P.
  
 CAST-IRON SOIL PIPES AND FITTINGS, AND THE COUPLINGS
 USED TO JOIN THESE PRODUCTS TOGETHER, SHALL BE
 THIRD-PARTY LISTED AND LABELED. THIRD-PARTY CERTIFIERS
 OR INSPECTORS SHALL COMPLY WITH THE MINIMUM INSPECTION
 REQUIREMENTS OF ANNEX A OR ANNEX A1 OF THE ASTM AND
 CISPI PRODUCT STANDARDS INDICATED IN THE CODE FOR SUCH
 PRODUCTS. NOT PROVIDED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  