| Date |
Text |
| 2021-08-17 13:07:58 | PLAN REVIEW / NFIP |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/RPX306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | CITY ORDINANCE NO. 4658-16 |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | CITY OF WEST PALM BEACH ORDINANCE NO. 4658-16 |
| | AS OF OCTOBER 5, 2017, THE FEDERAL EMERGENCY MANAGEMENT |
| | AGENCY (FEMA) ESTABLISHED A NEW FLOOD INSURANCE RATE |
| | MAP (FIRM) UTILIZING THE RECENTLY COMPLETED FLOOD |
| | HAZARD DETERMINATION (FHD) FOR THE CITY OF WEST PALM |
| | BEACH, FL. |
| | |
| | NOTICE: |
| | |
| | PROPERTY IS LOCATED IN A SPECIAL FLOOD HAZARD AREA |
| | (SFHA). IT IS LOCATED IN ZONE AE WITH BASE FLOOD |
| | ELEVATIONS OF 12.2 FEET NAVD. DESIGN FLOOD ELEVATION |
| | SHALL BE NOT LESS THAN 14.2 FEET NAVD. |
| | |
| | 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED |
| | |
| | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS |
| | REQUIRED AT TIME OF PERMIT APPLICATION. |
| | |
| | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS |
| | REQUIRED AT PLACEMENT OF 1ST FLOOR. |
| | SUBMIT TO BUILDING DEPARTMENT FOR REVIEW. |
| | |
| | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS |
| | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL |
| | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. |
| | NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL |
| | GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE |
| | BUILDING. |
| | |
| | |
| | FLOOD OPENINGS |
| | |
| | FBC R 322.2.2 ENCLOSURES BELOW DESIGN FLOOD ELEVATION. |
| | FULLY ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION |
| | SHALL BE AT OR ABOVE GRADE ON ALL SIDES AND CONFORM TO |
| | THE FOLLOWING: |
| | IN FLOOD HAZARD AREAS NOT SUBJECT TO HIGH-VELOCITY WAVE |
| | ACTION, ENCLOSED AREAS SHALL HAVE FLOOD OPENINGS TO |
| | ALLOW FOR THE AUTOMATIC INFLOW AND OUTFLOW OF |
| | FLOODWATERS. |
| | |
| | OPTIONS: |
| | |
| | FLOOD OPENING |
| | |
| | 1) PROVIDE FLOOD OPENINGS DESIGNED BY A DESIGN |
| | PROFESSIONAL PER R322.2.2 ENCLOSED AREA BELOW DESIGN |
| | FLOOD ELEVATION. |
| | 2) SIGNATURE AND SEAL OF DESIGNER IS REQUIRED. |
| | |
| | ENGINEERED FLOOD VENTS |
| | |
| | 1) PROVIDE ENGINEERED FLOOD VENTS. (SMART VENTS) |
| | 2) ATTACH A COPY OF THE INDIVIDUAL ENGINEERED FLOOD |
| | VENT CERTIFICATION OR EVALUATION SERVICE REPORT ISSUED |
| | BY THE INTERNATIONAL CODE COUNCIL EVALUATION SERVICE |
| | (ICC ES). |
| | 3) PROVIDE FLORIDA PRODUCT APPROVALS OR MIAMI DADE |
| | NOA?S FOR PROPOSED SMART VENTS. |
| | 4) FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | 5) FLOOD OPENINGS SHALL BE INSTALLED PER |
| | R322.2.2.1INSTALLATION OF OPENINGS. |
| | 6) SHOW NUMBER AND LOCATION OF FLOOD OPENINGS ON |
| | FOUNDATION PLAN. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |