Plan Review Notes
Plan Review Notes For Permit 21061690
Permit Number 21061690
Review Stop P
Sequence Number 1
Notes
Date Text
2021-07-26 13:46:421) PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE POOL
 SHOWER FOR COMPLIANCE WITH ANSI A117.1-1986.
 2) THE OVERFLOW FROM THE COLLECTOR TANK CANNOT
 DISCHARGE TO THE SANITARY SYSTEM PER WPB CODE OF
 ORDINANCES CHAPTER 90, ART. III, SEC.90-126 (B) (5)
 UNLESS SPECIFICALLY AUTHORIZED BY THE CITY IN WRITING.
 PLEASE CONTACT MANNY GONZALEZ IN THE CITY'S ENGINEERING
 DEPARTMENT AT 561-494-1085 OR [email protected] FOR
 FURTHER DIRECTION.
 3) THE VOLUME OF WATER IN THE SUN SHELF SHALL BE
 FILTERED AND CHEMICALLY TREATED ONCE EVERY 60 MINUTES
 (1 HOUR) OR LESS PER FBC-BUILDING SEC.454.1.2.8.4.
 VERIFY COMPLIANCE ON THE PLANS.
 4) SHT. 4- PLUMBING NOTE #6 - SUCTION PIPING SHALL NOT
 EXCEED 6 FEET PER SECOND PER FBC-BUILDING
 SEC.454.1.6.5.8.
 5) SHT. 4 - PLUMBING NOTE #8 - PLASTIC PIPE SUBJECT TO
 A PERIOD OF PROLONGED SUNLIGHT EXPOSURE SHALL BE COATED
 TO PROTECT IT FROM ULTRAVIOLET LIGHT DEGRADATION PER
 FBC-BUILDING SEC.454.1.6.4.
 6) THE FLOW RATE THROUGH THE INLETS SHALL NOT EXCEED 20
 GPM PER FBC-BUILDING SEC.454.1.6.5.9.6. VERIFY ON THE
 PLANS THAT THIS FLOW RATE HAS NOT BEEN EXCEEDED.
 7) PAGE 6 - COLLECTOR TANK SEC. "A" - THERE IS AN ARROW
 AND LINE THAT REFERS TO A FLOW VALVE BUT NO VALVE IS
 SHOWN. CLARIFY.
 8) SUBMIT A COPY OF THE STATE OF FLORIDA DEPARTMENT OF
 HEALTH APPLICATION FOR THE OPERATING PERMIT WITH THE
 DEPARTMENT OF HEALTH'S STAMP OF RECEIPT ON IT PER FL.
 STATUTE 514.03 (1).
 9) SHT. 4 - THERE ARE NOTES THAT ARE OVERLAYED ONTO
 EACH OTHER BY THE POOL LADDER THAT MAKE THE NOTES
 ILLEGIBLE.PLEASE CLEAN UP THESE NOTES.
 10) SUPPLY TOTAL DYNAMIC HEAD CALCULATIONS TO SHOW THE
 CALCULATED FLOW RATE TO MEET THE TURNOVER RATE REQUIRED
 AND THE VELOCITY TO PROPERLY SIZE THE PIPING. APSP
 7-2013 SEC.4.4.9.2.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved