| Date |
Text |
| 2021-07-16 15:01:24 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THIS PROJECT IS FOR STRUCTURAL REPAIRS TO A |
| | MULTIFAMILY RENTAL APARTMENT. THE 2020 FBC RESIDENTIAL |
| | APPLIES TO DETACHED ONE- AND TWO- FAMILY DWELLINGS AND |
| | TOWNHOUSES AND DOES NOT APPLY TO THIS PROJECT PER |
| | FBC-R101.2. THE 2020 FBC EXISTING BUILDING AND 2020 FBC |
| | BUILDING WILL APPLY. |
| | |
| | 2) THE STRUCTURAL DAMAGE TO THE BUILDING WILL NEED TO |
| | BE ASSESSED BY A FLORIDA LICENSED DESIGN PROFESSIONAL. |
| | A SIGNED AND SEALED DAMAGE REPORT ALONG WITH SIGNED AND |
| | SEALED REPAIR PLANS ARE REQUIRED TO BE SUBMITTED. FBC |
| | EXISTING BUILDING 406.2 & FBC AMEND. 107.1 & 107.2.1.2 |
| | |
| | 3) THE PLANS ARE REQUIRED TO SPECIFY THE WIND LOAD |
| | DESIGN DATA, THE COMPONENT AND CLADDING PRESSURES FOR |
| | THE OPENINGS AND ANY OTHER RELEVANT DESIGN LOADS. FBC |
| | EXISTING BUILDING 406.2 & FBC 1609.3 |
| | |
| | 4) IF YOU INTEND TO REINSTALL THE WINDOWS REMOVED FROM |
| | THE DAMAGED WALL AREA, THE ENGINEER WILL BE REQUIRED TO |
| | EVALUATE THOSE WINDOWS TO DETERMINE THAT THEY ARE NOT |
| | DAMAGED AND ARE SUITABLE TO BE USED IN THE |
| | RECONSTRUCTED WALL. FBC EXISTING BUILDING 406.2 |
| | |
| | 5) ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO |
| | HAVE THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON |
| | THEM. YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND |
| | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC |
| | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE |
| | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT |
| | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL |
| | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE |
| | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE |
| | SIGNATURE ARE ACCEPTABLE. FS 487 & 61G1 OR FS 471 & |
| | 61G15 |
| | |
| | 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| | CITY RE-SUBMITTAL FORM. |