| Date |
Text |
| 2021-07-16 13:37:50 | PLAN REVIEW BUILDING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | ROOFING PROVISO ON PLAN PAGE SP1.0 |
| | |
| | 1. PROVIDE A WINDOW AND DOOR SCHEDULE. INCLUDE THE |
| | FOLLOWING INFORMATION. |
| | |
| | 1. LOCATION REFERENCE TO OPENING NUMBER ON PLAN. |
| | 2. DEVICE TYPE WINDOW/DOOR/SHUTTER |
| | 3. ROUGH OPENING WXH (AREA SF) |
| | 4. DESIGN PRESSURES TABLE R301.1.(2) OR ASCE 7-16 |
| | 5. NOA OR FL NUMBER |
| | 6. MAX DESIGN PRESSURE FROM NOA OR FL |
| | 7. IDENTIFY EGRESS OPENINGS |
| | |
| | 2. PRODUCT APPROVAL FL20468-R3 HAS EXPIRED. PROVIDE A |
| | PRODUCT APPROVAL VALID FOR THE 2020 FBC. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 3. GARAGE IS BEING CONVERTED TO CONDITIONED SPACE. PALM |
| | BEACH COUNTY IMPACT FEES MAY APPLY. SEE COMMENTS UNDER |
| | IMPACT REVIEW. |
| | 3A) PROVIDE AN ENERGY SUBMITTAL |
| | 3B) IDENTIFY CEILING AND WALL INSULATION. |
| | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. |
| | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 |
| | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE |
| | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE |
| | COMPLIANCE BY SECTION 405. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |