| Plan Review Notes For Permit 21061233 |
| Permit Number |
21061233 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-07-29 11:17:29 | REPLACE BALCONY | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected]. | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENTS | | | | | | CORRECTIONS NEEDED - | | | 1) PLEASE SHOW STAIR TREAD DEPTH TO COMPLY WITH FBC | | | 1011.5.2 (3.) IN GROUP R-3 OCCUPANCIES; WITHIN DWELLING | | | UNITS IN GROUP R-2 OCCUPANCIES; AND IN GROUP U | | | OCCUPANCIES THAT ARE ACCESSORY TO A GROUP R-3 OCCUPANCY | | | OR ACCESSORY TO INDIVIDUAL DWELLING UNITS IN GROUP R-2 | | | OCCUPANCIES; THE MAXIMUM RISER HEIGHT SHALL BE 73/4 | | | INCHES (197 MM); THE MINIMUM TREAD DEPTH SHALL BE 10 | | | INCHES (254 MM); | | | 2) PLEASE SHOW SOLID RISERS PER FBC 1011.5.5.3 SOLID | | | RISERS. EXCEPTIONS: 1.SOLID RISERS ARE NOT REQUIRED FOR | | | STAIRWAYS THAT ARE NOT REQUIRED TO COMPLY WITH SECTION | | | 1009, PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT | | | PERMIT THE PASSAGE OF A SPHERE WITH A DIAMETER OF 4 | | | INCHES (102 MM). |
|