Plan Review Notes
Plan Review Notes For Permit 21061062
Permit Number 21061062
Review Stop B
Sequence Number 1
Notes
Date Text
2021-07-19 09:00:59PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) CLARIFY WHY THE OCCUPANCY TYPE IS SPECIFIED AS B
 (BUSINESS) FOR THIS SINGLE FAMILY RESIDENCE. THIS
 PROPERTY IS ZONED SINGLE FAMILY RESIDENTIAL. FBC AMEND.
 107.2.1
  
 2) THE CONSTRUCTION TYPE IS SPECIFIED AS III-B. THIS
 CONSTRUCTION TYPE REQUIRES THE EXTERIOR BEARING WALLS
 TO HAVE A 2 HOUR FIRE-RESISTIVE RATING PER FBC TABLE
 601. THE TYPICAL 8" CONCRETE IN FLORIDA DOES NOT
 PROVIDE A 2 HOUR FIRE-RESISTIVE RATING. SHOW HOW THE
 REQUIRED FIRE-RESISTIVE RATING WILL BE MET. FBC AMEND.
 107.2.1
  
 3) SUBMIT PRODUCT APPROVALS THAT HAVE BEEN APPROVED IN
 WRITING BY THE DESIGN PROFESSIONAL. FBC 107.3.4 -
 PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 PER
 FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE
 TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS
 INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN
 PRESSURES FOR EACH OF THE DIFFERENT ROOFING MATERIALS,
 WINDOW (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR
 DOOR TYPES.
  
 4) SUBMIT A SURVEY AND SITE PLAN. FBC 107.2.5 THE
 CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION
 FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING
 TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND
 EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT
 LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED
 FINISHED GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS,
 FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE
 DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE
 SURVEY. IN THE CASE OF DEMOLITION, THE SITE PLAN SHALL
 SHOW CONSTRUCTION TO BE DEMOLISHED AND THE LOCATION AND
 SIZE OF EXISTING STRUCTURES AND CONSTRUCTION THAT ARE
 TO REMAIN ON THE SITE OR PLOT.
  
 5) SUBMIT THE REQUIRED DOCUMENTS TO SHOW COMPLIANCE
 WITH THE FBC ENERGY CONSERVATION R401.2.
  
 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A
 RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE
 CITY RE-SUBMITTAL FORM.
  
  
  