| Date |
Text |
| 2021-07-19 09:00:59 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) CLARIFY WHY THE OCCUPANCY TYPE IS SPECIFIED AS B |
| | (BUSINESS) FOR THIS SINGLE FAMILY RESIDENCE. THIS |
| | PROPERTY IS ZONED SINGLE FAMILY RESIDENTIAL. FBC AMEND. |
| | 107.2.1 |
| | |
| | 2) THE CONSTRUCTION TYPE IS SPECIFIED AS III-B. THIS |
| | CONSTRUCTION TYPE REQUIRES THE EXTERIOR BEARING WALLS |
| | TO HAVE A 2 HOUR FIRE-RESISTIVE RATING PER FBC TABLE |
| | 601. THE TYPICAL 8" CONCRETE IN FLORIDA DOES NOT |
| | PROVIDE A 2 HOUR FIRE-RESISTIVE RATING. SHOW HOW THE |
| | REQUIRED FIRE-RESISTIVE RATING WILL BE MET. FBC AMEND. |
| | 107.2.1 |
| | |
| | 3) SUBMIT PRODUCT APPROVALS THAT HAVE BEEN APPROVED IN |
| | WRITING BY THE DESIGN PROFESSIONAL. FBC 107.3.4 - |
| | PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 PER |
| | FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE |
| | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS |
| | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN |
| | PRESSURES FOR EACH OF THE DIFFERENT ROOFING MATERIALS, |
| | WINDOW (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR |
| | DOOR TYPES. |
| | |
| | 4) SUBMIT A SURVEY AND SITE PLAN. FBC 107.2.5 THE |
| | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| | FINISHED GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS, |
| | FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE |
| | DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE |
| | SURVEY. IN THE CASE OF DEMOLITION, THE SITE PLAN SHALL |
| | SHOW CONSTRUCTION TO BE DEMOLISHED AND THE LOCATION AND |
| | SIZE OF EXISTING STRUCTURES AND CONSTRUCTION THAT ARE |
| | TO REMAIN ON THE SITE OR PLOT. |
| | |
| | 5) SUBMIT THE REQUIRED DOCUMENTS TO SHOW COMPLIANCE |
| | WITH THE FBC ENERGY CONSERVATION R401.2. |
| | |
| | 6) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| | CITY RE-SUBMITTAL FORM. |
| | |
| | |
| | |