| Plan Review Notes For Permit 21060788 |
| Permit Number |
21060788 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-10-05 07:14:53 | PETER E VALENTI | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | ROOFING REVIEW DENIED: | | | | | | FBC B 107.2.1, PROVIDE THE ROOF MATERIAL PRODUCT | | | APPROVALS FOR SHINGLES AND UNDERLAYMENT. | | | | | | FBC R 905.1.1.1, PROVIDE THE METHOD OF UNDERLAYMENT | | | APPLICATION PER THE SECTION OF FBC R 905.1.1.1: | | | 1) SELF ADHERING UNDERLAYMENT. | | | 2) 4" WIDE STRIPS AT SHEATHING JOINTS BELOW THE | | | UNDERLAYMENT. | | | 3) 3.75" WIDE STRIPS OF SELF ADHERING FLASHING TAPE | | | STRIPS AT SHEATHING JOINTS BELOW UNDERLAYMENT. | | | | | | NOTE: A ROOFING SUB-PERMIT IS REQUIRED PRIOR TO ANY | | | ROOF WORK. |
|