| Date |
Text |
| 2021-07-13 11:16:44 | ALTERATION BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21060535 |
| | |
| | NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE. |
| | |
| | 1- PLANS ARE MISSING THE INFORMATION OF CABINETRY AT |
| | NEW NURSES STATION, BUSINESS OFFICE, ETC, SHOWING |
| | COMPLIANCE WITH THE ACCESSIBILITY REQUIREMENTS OF SEC. |
| | 902 FBC-ACCESSIBILITY. |
| | SEC. 806 FBC-EXISTING BUILDING AND SEC. 902 |
| | FBC-ACCESSIBILITY. |
| | |
| | 2- TYPICAL WALL SECTION ON SHEET A-1 SHOW FASTENING OF |
| | THE PARTITION TO THE SUSPENDED CEILING. TYPICALLY, THE |
| | PARTITIONS ARE BRACED TO THE STRUCTURAL CEILING, NOT |
| | THE SUSPENDED CEILING IN ORDER TO PROVIDE ADEQUATE |
| | STIFFNESS AS REQUIRED BY SEC. 1607.14 FBC-BUILDING. |
| | REVISE DETAIL AS REQUIRED OR PROVIDE CALCULATIONS |
| | SHOWING THAT SUSPENDED CEILING WILL PROVIDE THE |
| | REQUIRED STIFFNESS. SEC. 107.2.1.2 CITY AMENDMENTS. |
| | |
| | 3- WALL LEGEND AND LETTERS KEYED ON THE FLOOR PLAN |
| | DON'T MATCH. THEY NEED TO BE COORDINATED. CHECK LETTERS |
| | C AND D AND REVISE AS REQUIRED. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | 4- ALL DRAWINGS (COVER SHEET, A-1 AND E-1) NEED |
| | ARCHITECT'S ORIGINAL SEAL/SIGNATURE AS REQUIRED BY SEC. |
| | 481 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. |
| | PLANS WERE SUBMITTED ELECTRONICALLY. NEED PLANS WITH |
| | ARCHITECT'S DIGITAL SIGNATURE OR PROVIDE HARD COPY |
| | PLANS WITH THE ORIGINAL SEAL AND SIGNATURE. |
| | NOTE: COVER SHEET IS MISSING THE ARCHITECT'S TITLE |
| | BLOCK. |
| | |
| | |
| | ARCHITECTS |
| | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND |
| | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| | |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |