| Date |
Text |
| 2022-02-08 12:05:28 | 02/08/22 2ND PLUMBING REVIEW**DENIED** WITH COMMENTS |
| | |
| | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| | |
| | 1. ON SHEET A0.04; |
| | |
| | A. DONE |
| | |
| | B. DONE |
| | |
| | C. DONE |
| | |
| | 2. ON SHEET A0.11; |
| | |
| | A. DONE |
| | |
| | B. DONE |
| | |
| | C. DONE |
| | |
| | D. DONE |
| | |
| | 3. DONE |
| | |
| | 4. ON SHEET, A0.13; |
| | |
| | A. DONE |
| | |
| | B. DONE |
| | |
| | C. DONE |
| | |
| | D. DONE |
| | |
| | E. DONE |
| | |
| | F. TOILET SAYS 30 INCHES FROM THE BACK, AND THE TOILET |
| | PAPER DISPENSERS SHALL BE 7 INCHES MINIMUM AND 9 INCHES |
| | MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE |
| | CENTERLINE OF DISPENSER PER THE 2020 FBC ACC SEC. |
| | 604.7. |
| | |
| | 5. DONE |
| | |
| | 6. DONE AND COMMENT ON NEW INFORMATION SUBMITTED...ON |
| | SHEET A6.01, .02, .03 .04, .05, .11, .12, .13, .14, |
| | .15, .16, .17, 18, .21, .22, .31, .32, .33, .34, .35, |
| | .36, .37 AND .38 WOULD YOU LABEL AS TO THE |
| | CORRESPONDING FHA TYPE A OR B PER THE DESIGN MANUAL IF |
| | APPLICABLE, CLARIFY PER THE WPB AMENDMENTS TO THE FBC |
| | SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | COMMENT ON NEW INFORMATION SUBMITTEDT, |
| | |
| | A. ON SHEET A6.06, .07, .19 .40, NO BACKING IS SHOWN |
| | FOR THE VERTICAL GRAB BARS. WOULD YOU PLEASE CORRECT |
| | PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 |
| | INFORMATION ON CONSTRUCTION DOCUMENTS? |
| | |
| | B. ON SHEET A6.32, .34, .36 HAS TYPE B AND TYPE A PER |
| | THE DESIGN MANUAL. IF SPECIFICATION A IS SELECTED AS |
| | THE BASIS FOR DESIGNING A BATHROOM, ALL BATHROOMS IN |
| | THE DWELLING UNIT MUST COMPLY WITH SPECIFICATION A. IT |
| | CANNOT BE COMBINED PER P 7.34. WOULD YOU PLEASE CORRECT |
| | PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 |
| | INFORMATION ON CONSTRUCTION DOCUMENTS? |
| | |
| | |
| | 7. DONE. |
| | |
| | 8. DONE |
| | |
| | 9. DONE |
| | |
| | 10. ON SHEET A7.10 AND A 7.11 19; |
| | |
| | A. DONE |
| | |
| | B. DONE |
| | |
| | C. WOULD YOU PLEASE IDENTIFY THE RESTROOM AS ACCESSIBLE |
| | FOR WOMEN'S AND MEN'S PER THE WPB AMENDMENTS TO THE FBC |
| | SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | 11. NOT DONE...ON SHEET P100 UNDER PLUMBING EQUIPMENT |
| | SCHEDULE, IT HAS AN ASSE, AND THE TEMP OF 110 IS |
| | MISSING. WOULD YOU PLEASE ADD PER THE WPB AMENDMENTS TO |
| | THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION |
| | DOCUMENTS? NO P100 V3 IN DRAWINGS. |
| | |
| | 12. ON SHEET P3.01. |
| | |
| | A. DONE |
| | |
| | B. NOT DONE...THE KITCHEN SINKS HAVE NO DRAIN |
| | CONNECTIONS. WOULD YOU PLEASE PROVIDE PER THE WPB |
| | AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS? |
| | |
| | 13. ON SHEET P3.03; |
| | |
| | A. DONE |
| | |
| | B. DONE |
| | |
| | C. IT SEEMS THAT THE HUB DRAIN IS IN THE ELEVATOR PITS, |
| | AND THEY NEED TO BE OUTSIDE THE ELEVATOR PER THE 2020 |
| | FBC SEC. B 3002.9 |
| | |
| | 14. ON SHEET P3.04; |
| | |
| | A. DONE |
| | |
| | B. DONE |
| | |
| | C. DONE |
| | |
| | D. DONE |
| | |
| | 15. DONE |
| | |
| | 16. DONE |
| | |
| | 17. DONE |
| | |
| | 18. ON SHEET P4.01 AND ANY THAT APPLY WHICH ARE |
| | SIMILAR, |
| | |
| | A. THE WASHING MACHINE SHUT-OFF VALVES SHALL BE |
| | ACCESSIBLE WITHOUT MOVING THE UNIT AND WITHIN REACH PER |
| | THE 2020 FBC SEC. P 606.3 ACCESS TO VALVES. |
| | |
| | B. DONE |
| | |
| | 19. DONE. |
| | |
| | 20. DONE. |
| | |
| | 21. DONE. |
| | |
| | 22. DONE, BUT NO CLEANOUTS SHOWN...WOULD YOU PLEASE |
| | PROVIDE AN ISOMETRIC DRAWING OF ALL STORM LINES AND |
| | THEIR CONNECTIONS PER THE WPB AMENDMENTS TO THE FBC |
| | SEC. 107.5.1.3 (13) COMMERCIAL PLUMBING. |
| | |
| | 23. ON SHEET C4.2, THE BACKFLOW REQUIRES A SEPARATE |
| | PERMIT. WOULD YOU PLEASE PROVIDE PER THE WPB AMENDMENTS |
| | TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION |
| | DOCUMENTS? |
| | |
| | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA |
| | |
| | WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON |
| | REQUEST. |
| | |
| | LUIS A. CRESPO |
| | PLUMBING PLAN EXAMINER / INSPECTOR |
| | EMAIL: [email protected] OFFICE: 561 805-6720 |
| | |