| 2021-06-17 16:41:11 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1 |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 |
| | 7TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 1ST REVIEW |
| | |
| | PLUMBING COMMENTS: DENIED |
| | |
| | 1.IN CONVERSATION WITH THE CONTRACTOR, IT WAS NOTED |
| | THAT THE GUEST BATH HAS AN EXISTING BATHTUB THAT IS TO |
| | REMAIN. THE PLANS SHOW A SHOWER. PER WPB FBC 107.2.1, |
| | NOTE EXISTING BATHTUB AND PROVIDE NOTE STATING |
| | ?EXISTING BATHTUB TO REMAIN? ON ALL PLANS (SEE REDLINED |
| | COMMENTS ON REVIEWED PLANS). DELETE THE WORD ?SHOWER? |
| | IN THE GUEST BATH NOTES IN THE GUEST BATH NOTES ON THE |
| | PROPOSED PLAN. |
| | |
| | 2.ADD NOTE ?PER FBC PL 412.3, NEW SHOWER VALVE SHALL BE |
| | BALANCED-PRESSURE, THERMOSTATIC OR COMBINATION |
| | BALANCED-PRESSURE/THERMOSTATIC AND CONFORM TO THE |
| | REQUIREMENTS OF ASSE 1016/ASME A112.1016/CSA B125.16 OR |
| | ASME A112.18.1/CSA B125.1 AND SHALL BE INSTALLED AT THE |
| | POINT OF USE.? |
| | |
| | 3.FBC PL 421.4.1 BATHTUB FLOORS, SHOWER FLOORS, WALL |
| | AREAS ABOVE BUILT-IN TUBS THAT HAVE INSTALLED SHOWER |
| | HEADS AND WALLS IN SHOWER COMPARTMENTS SHALL BE |
| | CONSTRUCTED OF SMOOTH, CORROSION-RESISTANT AND |
| | NONABSORBENT WATERPROOF MATERIALS. WALL MATERIALS SHALL |
| | EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE |
| | ROOM FLOOR LEVEL, AND NOT LESS THAN 70 INCHES ABOVE THE |
| | DRAIN OF THE TUB OR SHOWER. SUCH WALLS SHALL FORM A |
| | WATER-TIGHT JOINT WITH EACH OTHER AND WITH EITHER THE |
| | TUB OR SHOWER FLOOR. PER WPB FBC 107.2.1 PROVIDE THIS |
| | INFORMATION ON THE PLAN |
| | |
| | 4.PROVIDE A PLUMBING PLAN IDENTICAL TO THE PROPOSED |
| | PLAN, BUT TITLED ?PLUMBING PLAN?. THE CONTRACTOR?S |
| | NAME, SIGNATURE AND PLUMBING CERTIFICATION NUMBER SHALL |
| | BE ON THE DOCUMENT IN ACCORDANCE WITH WPB FBC |
| | 107.3.4.3. |
| | |
| | PLEASE NOTE THAT I HAVE PROVIDED REDLINED COMMENTS ON |
| | THE PLANS REFLECTING THE COMMENTS. |
| | |
| | PLEASE NOTE THAT WHEN SCANNED DRAWINGS ARE SUBMITTED |
| | WITH CONTRACTOR'S PRINTED NAME, SIGNATURE AND LICENSE |
| | NUMBER IN ACCORDANCE WITH WPB FBC 107.3.4.3, A PAPER |
| | PLAN WITH WET SIGNATURE SHALL BE PROVIDED TO THE |
| | BUILDING DEPARTMENT FOR HARD RECORD FILE PRIOR TO |
| | ISSUANCE OF A PERMIT. |
| | |
| | |
| | END OF COMMENTS. |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED |
| | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| | |
| | |
| | |