Plan Review Notes
Plan Review Notes For Permit 21060411
Permit Number 21060411
Review Stop NFIP
Sequence Number 3
Notes
Date Text
2021-09-01 16:14:54PLAN REVIEW / NFIP
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16
  
 3RD REVIEW CONSTRUCTION DRAWING ELEVATION CERTIFICATE
  
 NOTICE:
  
 THE 2-STORY SFR ENCROACHES INTO A SPECIAL FLOOD HAZARD
 AREA (SFHA). FLOOD ZONE AE WITH A BASE FLOOD ELEVATION
 (BFE) OF 6.0 FEET NAVD. THE DESIGN FLOOD ELEVATION
 (DFE) SHALL BE NOT LESS THAN 8.0 FEET NAVD.
  
 3 ELEVATION CERTIFICATES (EC) ARE REQUIRED FOR THE
 2-STORY SFR
  
 THE CABANA AND TERRACE ARE NOT LOCATED IN A SFHA AND DO
 NOT REQUIRE EC'S.
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ELEVATIONS ON PLANS ARE IN NGVD. ELEVATIONS IN
 ELEVATION CERTIFICATE ARE IN NAVD 88. A CONVERSION
 FACTOR OF 1.519 HAS BEEN PROVIDED.
 THIS CONVERSION OF VERTICAL DATUM FROM NGVD TO NAVD
 WILL PLACE THE GARAGE FLOOR BELOW THE DESIGN FLOOD
 ELEVATION OF 8.0 FT NAVD (9.5 FT NGVD MINUS 1.519 =
 7.981 NAVD).
 THIS WILL REQUIRE THE ELEVATION OF THE GARAGE FLOOR OR
 THE INSTALLATION OF FLOOD OPENINGS FOR THE GARAGE.
  
 OPTIONS: 1) CHANGE THE VERTICAL DATUM ON PLANS TO
 NAVD88. THIS IS RECOMMENDED.
 2) RAISE THE GARAGE FLOOR .019 FT TO 9.519 NGVD
 3) ENTER CORRECT VALUES IN SECTION A9 (B), (C) AND (D).
 INSTALL REQUIRED FLOOD OPENING IN GARAGE.
  
 2. BASED ON THE CONVERSION FACTOR, ELEVATION OF C2(A)
 TOP OF BOTTOM FLOOR, SHOULD BE 8.481 NAVD AND C2(B)
 SHOULD BE 19.781NAVD. C2 (E THRU F) ARE PROPOSED AT
 THIS TIME BUT MAY NEED ADJUSTING.
  
 NOTICE:
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR. SUBMIT THIS EC
 PRIOR TO COMMENCING WORK.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
 NOTE: YOU MAY SUBMIT THIS EC FOR REVIEW AFTER FINAL
 GRADE AND PLACEMENT OF EQUIPMENT SERVICING THE
 BUILDING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  