| 2021-07-14 10:38:18 | PLAN REVIEW ROOFING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. ROOFING PERMIT REQUIRED. |
| | PERMITS - 105.1 REQUIRED. |
| | |
| | 2. PROVIDE PRODUCT APPROVALS |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 3. SPECIFY UNDERLAYMENT PER FBCR CHPT. 9 |
| | R905.1.1UNDERLAYMENT. |
| | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL |
| | CONFORM TO THE APPLICABLE STANDARDS LISTED IN THIS |
| | CHAPTER. UNDERLAYMENT MATERIALS REQUIRED TO COMPLY WITH |
| | ASTM D226, D1970, D4869 AND D6757 SHALL BEAR A LABEL |
| | INDICATING COMPLIANCE TO THE STANDARD DESIGNATION AND, |
| | IF APPLICABLE, TYPE CLASSIFICATION INDICATED. |
| | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL BE |
| | APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION |
| | R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE. |
| | EXCEPTION: COMPLIANCE WITH SECTION R905.1.1.1 IS NOT |
| | REQUIRED FOR STRUCTURAL METAL PANELS THAT DO NOT |
| | REQUIRE A SUBSTRATE OR UNDERLAYMENT. |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |