| 2022-01-06 10:58:32 | BUILDING PLAN REVIEW |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | 2ND REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | NOTICE: CHANGE IN SOW. DEMO EXISTING STRUCTURE. BUILD |
| | NEW SFR. |
| | |
| | 1. A SEPERATE DEMO PERMIT IS REQUIRED. SUBMIT DEMO |
| | APPLICATION TO [email protected] |
| | |
| | DEMO CHECKLIST: |
| | |
| | THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A |
| | DEMO PERMIT PER FLORIDA BUILDING CODE, BUILDING 3303: |
| | |
| | 1. UTILITY RELEASE - FLORIDA POWER & LIGHT (ELECTRIC) |
| | RELEASE OF SERVICE CONFIRMATION |
| | |
| | 2. UTILITY RELEASE - FLORIDA PUBLIC UTILITIES (GAS) |
| | RELEASE OF SERVICE CONFIRMATION |
| | |
| | 3. UTILITY RELEASE - CITY OF WEST PALM BEACH WATER |
| | DEPARTMENT, REQUEST FOR METER PULL, ON THEIR FORM |
| | "DEMOLITION APPLICATION" |
| | |
| | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| | UILDING-PERMIT-FORMS |
| | |
| | IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED, |
| | THEN A PARTIAL RELEASE WILL BE NOTED ON THEIR FORM. |
| | |
| | 4. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT |
| | APPLICATION TO BUILDING DIVISION); SCHEDULE A FINAL |
| | PLUMBING INSPECTION #703. |
| | |
| | 5. EXTERMINATION LETTER - LETTER FROM A LICENSED PEST |
| | CONTROL COMPANY STATING THAT DEMOLITION ADDRESS HAS |
| | BEEN INSPECTED AND/OR TREATED FOR RODENTS. |
| | |
| | 6. COMPLETE THE DEMO DEBRIS FORM: |
| | |
| | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B |
| | UILDING-PERMIT-FORMS |
| | |
| | 7. PROVIDE A SITE PLAN OR SURVEY SHOWING LOCATION OF |
| | THE STRUCTURE(S) TO BE DEMOLISHED, FBC 107. |
| | |
| | 8.PROVIDE A STORMWATER POLLUTION PREVENTION PLAN. |
| | YOU MAY USE THE SURVEY. SHOW SILT FENCEING OR OTHER |
| | APPROVED METHODS |
| | |
| | 9.ASBESTOS |
| | |
| | PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE CONTRACTOR, |
| | ON LETTERHEAD, STATING THAT: |
| | |
| | THE INSTRUCTIONS ON THE WEBSITE OF THE ASBESTOS PROGRAM |
| | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH |
| | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE |
| | GIVEN TIMELY. |
| | |
| | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS |
| | CAN BE FOUND ON THEIR WEBSITE: |
| | |
| | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE |
| | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- |
| | RENOVATION.HTML |
| | |
| | |
| | COMMENTS FOR NEW SFR: |
| | |
| | NOTICE: VALUE HAS BEEN ADJUSTED TO $142,974.00 PER THE |
| | ICC BUILDING VALUATION DATA. |
| | |
| | 1. PROVIDE A SITE DRAINAGE PLAN WITH A BOUNDRY LINE |
| | SURVEY PER FBC R401.3 |
| | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| | INCLUDED BOUNDARY LINE SURVEY. |
| | FBC R401.3 SITE DRAINAGE |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| | DOES NOT CREATE A HAZARD. |
| | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM |
| | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 |
| | INCHES WITHIN THE FIRST 10 FEET. |
| | |
| | |
| | 2. PROVIDE THE FINISHED FLOOR ELEVATION |
| | R403.1.7.3 FOUNDATION ELEVATION. |
| | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION |
| | SHALL EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER |
| | AT POINT OF DISCHARGE OR THE INLET OF AN APPROVED |
| | DRAINAGE DEVICE A MINIMUM OF 12 INCHES (305 MM) PLUS 2 |
| | PERCENT. ALTERNATE ELEVATIONS ARE PERMITTED SUBJECT TO |
| | THE APPROVAL OF THE BUILDING OFFICIAL, PROVIDED IT CAN |
| | BE DEMONSTRATED THAT REQUIRED DRAINAGE TO THE POINT OF |
| | DISCHARGE AND AWAY FROM THE STRUCTURE IS PROVIDED AT |
| | ALL LOCATIONS ON THE SITE. |
| | FINISHED FLOOR ELEVATIONS SHALL BE PLACED ON FOUNDATION |
| | PLAN AND/OR FLOOR PLAN. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |