Plan Review Notes
Plan Review Notes For Permit 21051546
Permit Number 21051546
Review Stop ENG
Sequence Number 2
Notes
Date Text
2021-12-09 09:00:07PASSED WITH PROVISOS:
  
 CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB
 CONSTRUCTION STANDARD DETAIL GC-5 (WHEN DISTANCE
 BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER),
 OR STANDARD DETAIL GC-6 (WHEN DISTANCE BETWEEN CURB OR
 EDGE OF PAVEMENT IS LESS THAN 10 FT.) CITY STANDARD
 DETAIL IS REQUIRED, SEE HTTPS://WWW.WPB.ORG/GOVERNMENT/
 ENGINEERING/ENGINEERING-STANDARDS-DETAILS
  
 MAINTAIN AND SHOW MIN. 3 FT. SETBACK OF PROPOSED
 DRIVEWAY FROM NEIGHBORING PROPERTY LINE.
  
 THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS
 PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES,
 YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL
 BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR
 DEMOLITION WORK. INFORMATION CAN BE FOUND HERE:
 HTTP://WWW.SUNSHINE811.COM/
  
 ZONING DEPT. MAY HAVE ADDITIONAL COMMENTS; PLEASE
 RESUBMIT AFTER ALL REVIEW COMMENTS HAVE BEEN PROVIDED.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  