| Date |
Text |
| 2021-12-14 16:40:36 | BUILDING ALTERATION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE SHOW WALL FINISH AT MOP SINK TO COMPLY WITH |
| | FBC 1210.2.2 WALLS AND PARTITIONS. |
| | WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| | SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| | HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| | THAN 4 FEET (1219 MM) ABOVE THE FLOOR (DRYWALL IS NOT |
| | CONSIDERED A HARD SURFACE). |
| | |
| | 2) DRAWING A3.1 SHOWS RAMP BOTTOM HANDRAIL EXTENSION TO |
| | BE ON THE RAMP - HANDRAIL EXTENSIONS SHALL BE BEYOND |
| | THE RAMP FBC ACCESSIBILITY 505.10.1TOP AND BOTTOM |
| | EXTENSION AT RAMPS. |
| | RAMP HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE |
| | LANDING FOR 12 INCHES (305 MM) MINIMUM BEYOND THE TOP |
| | AND BOTTOM OF RAMP RUNS. EXTENSIONS SHALL RETURN TO A |
| | WALL, GUARD, OR THE LANDING SURFACE, OR SHALL BE |
| | CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN. |
| | |
| | 3) PLEASE SHOW TOP AND BOTTOM HANDRAIL EXTENSIONS AT |
| | THE STAIRS TO COMPLY WITH FBC 1014.6 HANDRAIL |
| | EXTENSIONS. |
| | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING |
| | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN |
| | ADJACENT FLIGHT OF STAIRS OR RAMP RUN. WHERE HANDRAILS |
| | ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL |
| | EXTEND HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) |
| | BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE |
| | DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. |
| | |
| | 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET REAR |
| | GRAB BAR LOCATION DIMENSIONS FROM THE CENTER OF THE |
| | TOILET PER FBC A 604.5.2 REAR WALL. |
| | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG |
| | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 |
| | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. |
| | |
| | 5) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER |
| | HOLDER LOCATION DIMENSIONS PER FBC A 604.7 DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| | INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| | SHALL NOT BE LOCATED BEHIND GRAB BARS. |
| | |
| | 6) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR |
| | LOCATION DIMENSIONS FROM THE FINISHED FLOOR TO THE |
| | "REFLECTIVE SURFACE" FBC 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | |