| 2021-06-18 14:23:11 | 1ST REVIEW FBC-2020 RES. |
| | PERMIT- 21051085 |
| | 6/18/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) PLEASE PROVIDE A LEGIBLE PLAN DRAWN AT A MINIMUM 1/8 |
| | INCH PER FT. SCALE THAT CLEARLY DEPICTS THE INTENDED |
| | SCOPE OF WORK FOR THE GARAGE. THE NOTES ON THE CURRENT |
| | DRAWING INDICATE "CLOSE THIS SIDE". THE PALM BEACH |
| | COUNTY PROPERTY APPRAISERS WEBSITE INDICATES THE GARAGE |
| | IS ACTUALLY AN EXISTING CARPORT. IT APPEARS THAT |
| | POSSIBLY THE INTENTION IS CLOSE THE OPEN WALLS OF THE |
| | CARPORT AND CREATE NEW LIVING OR STORAGE SPACE. IF THIS |
| | IS THE INTENTION, PLEASE PROVIDE THE NEW USE OF THE |
| | CARPORT AND PROVIDE A SCOPE OF WORK OUTLINE ON THE PLAN |
| | THAT ITEMIZING ALL PHASES OF BUILDING, ELECTRICAL, |
| | PLUMBING, AND MECHANICAL WORK- SECTION 107.2.1 WPB. |
| | PLEASE PROVIDE DRAWINGS, DETAILS, AND SPECIFICATIONS |
| | FOR ALL PROPOSED WORK. PLEASE NOTE THE PLANS SHALL BE |
| | DESIGNED IN ACCORDANCE WITH THE FBC RES- FLORIDA |
| | RESIDENTIAL BUILDING CODE 7TH EDITION 2020- SEE R101.2 |
| | FBC-RES. |
| | |
| | 2) PLEASE NOTE THAT NEW STRUCTURAL WORK ON THE EXISTING |
| | WALLS, OR INSTALLATION OF NEW ENCLOSURE WALLS WILL |
| | REQUIRE DRAWINGS AND DETAILS THAT ARE IN COMPLIANCE |
| | WITH SECTIONS R301.1 AND R301.2.1.1 FBC RES.- |
| | ALTERATIONS OF THE EXTERIOR WALLS OR NEW CONSTRUCTION |
| | OF EXTERIOR WALLS SHALL BE DESIGNED TO RESIST DEAD |
| | LOADS, LIVE LOADS, AND WIND LOADS. FOR ADDITIONAL CODE |
| | REQUIREMENTS BASED ON YOUR INTENDED USE OF THE SPACE |
| | PLEASE REVIEW CHAPTER 3 OF THE FBC RES AND PROVIDE |
| | COMPLIANT DRAWINGS AND DETAILS. |
| | |
| | 3) I HAVE COPIED SECTION R301.1. FBC RES BELOW FOR YOU, |
| | OR YOUR FLORIDA LICENSED DESIGN PROFESSIONAL (ARCHITECT |
| | OR ENGINEER) DESIGN TO REVIEW. PLEASE NOTE THAT ALL |
| | DRAWINGS AND DETAILS DESIGNED BY FL. LICENSED ENGINEERS |
| | AND ARCHITECTS SHALL BE SIGNED AND SEALED PER FL. |
| | STATUTES- 471 AND 481. ELECTRONICALLY TRANSMITTED PLANS |
| | SHALL BE DIGITALLY SIGNED AND SEALED IN ACCORDANCE WITH |
| | FL. STATUTES 471.025 AND 481.221, AND FAC 61G-15.23.005 |
| | & 61G1-16.005. |
| | |
| | R301.2.1.1 WIND DESIGN REQUIRED. |
| | IN REGIONS WHERE THE ULTIMATE DESIGN WIND SPEED, VULT, |
| | FROM FIGURE R301.2(4) EQUALS OR EXCEEDS 115 MILES PER |
| | HOUR (51 M/S), THE DESIGN OF CONCRETE, MASONRY, WOOD |
| | AND STEEL BUILDINGS FOR WIND LOADS SHALL BE IN |
| | ACCORDANCE WITH ONE OR MORE OF THE FOLLOWING METHODS: |
| | 1. 1. AWC WOOD FRAME CONSTRUCTION MANUAL (WFCM). |
| | 2. 2. CONCRETE AND MASONRY WALLS ARE PERMITTED TO BE |
| | DESIGNED IN ACCORDANCE WITH ICC STANDARD FOR |
| | RESIDENTIAL CONSTRUCTION IN HIGH-WIND REGIONS (ICC |
| | 600). |
| | 3. 3. ASCE MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER |
| | STRUCTURES (ASCE 7). |
| | 4. 4. AISI STANDARD FOR COLD-FORMED STEEL |
| | FRAMING?PRESCRIPTIVE METHOD FOR ONE- AND TWO-FAMILY |
| | DWELLINGS (AISI S230). |
| | 5. 5. FLORIDA BUILDING CODE, BUILDING; OR |
| | 6. 6. THE MAF GUIDE TO CONCRETE MASONRY RESIDENTIAL |
| | CONSTRUCTION IN HIGH WIND AREAS SHALL BE PERMITTED FOR |
| | APPLICABLE CONCRETE MASONRY BUILDINGS FOR A BASIC WIND |
| | SPEED OF 130 MPH (58 M/S) OR LESS IN EXPOSURE B AND 110 |
| | MPH (49 M/S) OR LESS IN EXPOSURE C IN ACCORDANCE WITH |
| | FIGURE R301.2(4) AS CONVERTED IN ACCORDANCE WITH |
| | R301.2.1.3. |
| | EXCEPTIONS: |
| | 1.FOOTINGS AND FOUNDATIONS SHALL COMPLY WITH CHAPTER 4. |
| | 2.EXTERIOR WINDOWS AND DOORS SHALL COMPLY WITH SECTION |
| | R609. |
| | 3.FOR STRUCTURAL INSULATED PANELS, THE PROVISIONS OF |
| | THIS CODE APPLY IN ACCORDANCE WITH THE LIMITATIONS OF |
| | SECTION R610. |
| | 4.EXTERIOR WALL COVERINGS AND SOFFITS SHALL COMPLY WITH |
| | CHAPTER 7. |
| | 5.ROOF SHEATHING SHALL BE ATTACHED IN ACCORDANCE WITH |
| | SECTION R803. |
| | 6.ROOF COVERINGS SHALL COMPLY WITH CHAPTER 9. |
| | 7.FOR CONCRETE CONSTRUCTION, THE PROVISIONS OF THIS |
| | CODE APPLY IN ACCORDANCE WITH THE LIMITATIONS OF |
| | SECTION R608.2. |
| | |
| | THIS FIRST REVIEW OF THE PROPOSED PROJECT IS STOPPED AT |
| | THIS POINT DUE TO THE LACK OF SUFFICENT PLANS AND |
| | INFORMATION. PLEASE NOTE THAT REVIEW OF RESUBMITTED |
| | PLANS MAY RESULT IN ADDITIONAL COMMENTS. WHEN |
| | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |