Plan Review Notes
Plan Review Notes For Permit 21050953
Permit Number 21050953
Review Stop L
Sequence Number 3
Notes
Date Text
2021-08-30 13:58:561. SATISFIED SECTION 94-445 (4) REQUIRED PLANT MATERIAL
 SPECIFICATIONS.
 SHADE AND FLOWERING TREES MINIMUM 12 FEET IN HEIGHT AND
 FLORIDA GRADE #1 OR BETTER QUALITY.
 PALM SPECIES MINIMUM EIGHT FEET CLEAR WOOD.
 SHRUBS MINIMUM OF 3GALLON, GROUNDCOVER MAY BE SMALLER.
 A. PROVIDE PLANT LIST WITH SPECIES, QUANTITIES AND
 SIZES. EXISTING TREES SHOULD BE INCLUDED ON PLANT LIST
 FOR TOTAL PLANT INVENTORY IN DESIGN.
  
 2. SATISFIED SECTION 94-445 I.
 PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT
 MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT
 TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE
 LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH
 FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH
 FLORIDA LANDSCAPES.
 A. PROVIDE TOTAL PERCENTAGE BASED ON PLAN LIST.
 INFORMATION MUST BE VISIBLE ON SUBMITTED DESIGN.
 8/10/21: INDICATE ON PLANT SCHEDULE WHAT PLANTS ARE
 NATIVE AND OR DROUGHT TOLERANT.
  
 3. PARTIALLY SATISFIED SECTION 94-442(C)(2)A. SINGLE
 FAMILY DWELLING UNITS
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
 ONE TREE REQUIRED FOR EACH 1,000 SQ. FT OF OPEN SPACE
 OR PORTION THEREOF
 ONE SHRUB REQUIRED FOR EACH 500 SQ. FT OF OPEN SPACE OR
 PORTION THEREOF.
 A. SHOW THE REQUIRED CALCULATION AND PROVIDED TREES AND
 SHRUBS BASED ON THE OPEN SPACE SQUARE FOOTAGE
 REQUIREMENTS. USE CALCULATION: LOT SIZE SQ. FT.
 SUBTRACTED BY HOME BUILDING FOOTPRINT EQUALS THE OPEN
 SPACE SQUARE FOOTAGE . POOLS, DRIVES SIDE WALKS SHOULD
 NOT BE COUNTED IN THE CALCULATION.
 8/10/21 SHOW CALCULATION ON PLAN. SHOW HOW MANY
 REQUIRED TREES PER 1000 SQ FT WILL BE INSTALLED . SHOW
 HOW MANY REQUIRED SHRUBS PER 500 SQ FT WILL BE
 INSTALLED.
 8/30/21 SEE COMMENT #8
  
 4. SATISFIED SECTION 94-442 (D) SUBSTITUTION OF PALM
 TREES.
 PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35
 PERCENT OF THE SHADE OR FLOWERING TREES REQUIRED BY
 THIS ARTICLE. HOWEVER, WHEN PALM TREES ARE SUBSTITUTED
 FOR SHADE TREES, THREE PALM TREES SHALL BE PROVIDED FOR
 EACH REQUIRED SHADE TREE. THIS 3:1 SUBSTITUTION SHALL
 NOT BE REQUIRED FOR ROYAL PALM TREES (ROYSTONEA SPP.),
 SENEGAL DATE PALM (PHOENIX RECLINATA), MEDJOOL DATE
 PALM (PHOENIX DACTYLIFERA), BISMARCK PALM (BISMARCKIA
 NOBILIS), AND SILVER DATE PALM (PHOENIX SYLVESTRIS).
 8/10/21: ONCE OPEN SPACE CALCULATION IS PROVIDED THEN
 35% PALM TO SHADE TREE RATIO CAN BE DETERMINED
  
 REVIEW COMMENTS 8/10/2021
 4. SATISFIED MULTI STEM LIVE OAK DOES NOT MEET FLORIDA
 GRADE 1 OR BETTER REQUIREMENTS.
  
 5. SATISFIED RECOMMEND CHANGING MULTI STEM BUTTONWOOD
 FOR SINGLE STEM
  
  
 6. SATISFIED FOX TAIL PALMS ARE LOCATED ON CITY PARK
 WAY. THEY CANNOT BE COUNTED ON LANDSCAPE PLAN.
  
 7. SATISFIED PLACE ALL TABLES /SCHEDULES ON ONE SHEET
 SO REVIEWER WILL NOT HAVE TO HUNT FOR INFORMATION
 THROUGH MULTIPLE SHEETS.
  
 REVIEW COMMENTS 8/30/2021
  
 8. OPEN SPACE 9,240 SQ FEET. REQUIRED TO ROUND TREE
 COUNT UP TO NEXT FULL NUMBER . ***10 TREES NEEDED** .
  
 ANDREW BURNETT
 561-822-1562


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved