| 2021-07-15 14:19:06 | 07/15/21 RESPONSE TO DENIS SHEA EMAIL . |
| | |
| | MR. GOMEZ, |
| | DO THE ATTACHED PDF?S TAKE CARE OF YOUR COMMENTS? |
| | PLEASE GIVE ME A CALL AT THE NUMBER BELOW WHEN YOU GET |
| | A CHANCE SO WE CAN DISCUSS THIS. |
| | THANK YOU |
| | DENIS SHEA |
| | OFFICE: (561) 586-8255 |
| | EMAIL: [email protected] |
| | CASTILLA AND GODOY COMPANIES |
| | STATE OF FLORIDA CERTIFIED GENERAL CONTRACTOR |
| | |
| | RESPONSE: |
| | 1) STC TESTING SUBMITTED IS FOR AN 8" CONCRETE SLAB |
| | WITH A SUSPENDED GYPSUM BOARD CEILING. THIS TEST IS FOR |
| | AN ASSEMBLY THAT DOESN'T MATCH EXISTING ASSEMBLY. |
| | EXISTING ASSEMBLY IN THIS BUILDING IS A 6" CONCRETE |
| | SLAB WITH NO ACOUSTICAL CEILING. NEED TO PROVIDE COPY |
| | OF TEST DONE ON THE 6" SLAB AND NO ACOUSTICAL CEILING. |
| | |
| | 2) PLEASE COORDINATE WITH PRIVATE PROVIDER. ANY |
| | RESUBMITAL NEEDS TO BE REVIEWED/APPROVED BY THE PRIVATE |
| | PROVIDER TO AVOID CONFLICTS/DELAYS. |
| | |
| | |
| | |
| | PREVIOUS COMMENT: |
| | |
| | 2ND AUDIT |
| | RESIDENTIAL(R2) ALTERATION . |
| | PERMIT #21050878 |
| | |
| | 1- OK |
| | |
| | ORIGINAL COMMENT |
| | 2- FLOORING SOUND INSULATION MATERIAL: |
| | A) OK |
| | |
| | B) PROVIDE COPY OF THE SOUND TRANSMISSION CLASS (STC) |
| | TEST DONE IN ACCORDANCE WITH ASTM E 90 AS REQUIRED BY |
| | SEC. 1207.2 OF FBC 7TH EDITION (2020). |
| | |
| | RESPONSE: |
| | SOUND TRANSMISSION CLASS (STC) TEST WAS NOT SUBMITTED. |
| | NEED TO PROVIDE COPY OF THE TEST AS DONE WITH THE |
| | IMPACT AND FLAME SPREAD TESTS SUBMITTED. |
| | NOTE: CRACK ISOLATION AND SOUND MEMBRANE DATA SHEET |
| | SUBMITTED IS NOT A COPY OF THE STC TEST AND THE |
| | INFORMATION ON THIS DATA SHEET IS ONLY FOR SOUND TEST |
| | DONE ON 8" CONCRETE SLAB WITH A SUSPENDED DRYWALL |
| | CEILING. SEE FOOTNOTE BELOW THE TECHNICAL DATA ITEM #4. |
| | THIS DATA SHEET DOESN'T APPLY TO THIS PROJECT. THIS IS |
| | WHY WE ASK FOR COPY OF THE TEST. |
| | |
| | |
| | C) OK. |
| | |
| | NOTE: TEST SAMPLES TO MATCH BUILDING FLOOR/CEILING |
| | CONSTRUCTION AND PROPOSED FLOOR FINISH. ALSO, THERE ARE |
| | TESTS FOR 6" OR 8" CONCRETE SLABS WITH OR WITHOUT |
| | ACOUSTICAL CEILING. TYPICALLY THERE ARE NOT SUSPENDED |
| | ACOUSTICAL CEILINGS IN THESE BUILDINGS. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |