| 2021-06-30 17:11:14 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21050513 |
| | |
| | 1-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. 606 |
| | FBC-EXISTING BUILDING AND SEC. R101.5 FBC-ENERGY |
| | CONSERVATION. |
| | NOTE: PLEASE MAKE SURE FORRMS ARE PROPERLY SIGNED BY |
| | ALL REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO |
| | AVOID CONFLICTS/DELAYS. |
| | |
| | 2- LOT DRAINAGE (SEC. 606 FBC-EXISTING BUILDING) |
| | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE |
| | FOLLOWING: |
| | R401.3 FBC-RESIDENTIAL. |
| | SEC. 107.2.5 CITY AMENDMENTS. |
| | SEC. 110.9 CITY AMENDMENTS. |
| | |
| | 3-PROVIDE SITE PLAN SHOWING THE LOCATION OF NEW |
| | CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE AND |
| | DISTANCES FROM LOT LINES. SITE PLAN TO BE DRAWN IN |
| | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| | LINE SURVEY. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. 107.2.5 CITY |
| | AMENDMENTS. |
| | |
| | 4- SHEET S1.1: |
| | (A)PARTIAL FLOOR PLAN: PROVIDE LAYOUT OF ROOMS ADJACENT |
| | TO THE PROPOSED ADDITION. NEED THIS TO VERIFY IF THERE |
| | ARE BEDROOMS ADJACENT TO THE ADDITION AND EXISTING |
| | EGRESS REQUIREMENTS ARE NOT CHANGED OR BLOCKED. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. 107.3.5.3 CITY |
| | AMENDMENTS. |
| | |
| | (B)PARCEL CONTROL NUMBER SHOWN UNDER DATA GATHERED FROM |
| | PAPA IS INCORRECT. REVISE AS REQUIRED. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | (C)REVISE DESIGN CRITERIA: WIND EXPOSURE DOESN'T MATCH |
| | WIND EXPOSURE IN TRUSS NOTE #1 ON SHEET S1.2. REVISE AS |
| | REQUIRED. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | (D)DESIGN CRITERIA SPECIFIES: FULLY OPEN DESIGN AND |
| | INTERNAL PRESSURE COEFFICIENT = N/A. THIS BUILDING IS |
| | NOT OPEN. REVISE AS REQUIRED. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | (E)REVISE BUILDING CATEGORY. THIS BUILDING IS NOT |
| | CATEGORY I. IT IS CATEGORY II. SEE SEC. 1604.5 |
| | FBC-BUILDING. |
| | SEC. 606 FBC-EXISTING BUILDING. |
| | |
| | (F) FOUNDATION PLAN DOESN'T PROVIDE SPECIFICATIONS FOR |
| | CONCRETE SLAB. PROVIDE COMPLETE SPECIFICATIONS. FOOTING |
| | SIZE, REINFORCEMENT, VAPOR BARRIER, ETC. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. 107.3.5.3 CITY |
| | AMENDMENTS. |
| | |
| | (G)WALL SECTION AND EXTERIOR ELEVATIONS DON'T SPECIFY |
| | THE ROOF PITCH. |
| | PROVIDE INFORMATION. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. R905.2 |
| | FBC-RESIDENTIAL. |
| | |
| | (H) WINDOW AND DOOR SCHEDULE. CLEARLY SPECIFY THE |
| | DESIGN PRESSURES FOR ALL DOORS AND WINDOWS. MISSING |
| | SOME. REVISE/UPDATE PRODUCT APPROVALS NUMBERS. SOME ARE |
| | EXPIRED. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | (I)WALL SECTION: SPECIFY ROOFING UNDERLAYMENT SHOWING |
| | COMPLIANCE WITH ANY OF THE OPTIONS OF SEC. R905.1.1.1 |
| | FBC-RESIDENTIAL. |
| | SEC. 606 FBC-EXISTING BUILDING. |
| | |
| | (J)WALL SECTION TO PROVIDE COMPLETE INFORMATION FOR |
| | SOFFIT CONSTRUCTION. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. R703.1.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | (K)WALL SECTION TO PROVIDE COMPLETE INFORMATION FOR |
| | ATTIC VENT. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. R806 |
| | FBC-RESIDENTIAL. |
| | |
| | (L)REVISE MASONRY BUCK DETAIL. BEVELED BUCKS ARE NOT |
| | ALLOWED. 2X4 BUCKS DON'T PROVIDE FULL SUPPORT TO THE |
| | DOOR FRAME AS REQUIRED BY R609.7.2.1 FBC-RESIDENTIAL. |
| | REVISE AS REQUIRED. |
| | SEC. 606 FBC-EXISTING BUILDING. |
| | |
| | 5- PROVIDE COMPLETE INFORMATION FOR ATTACHMENT OF |
| | PROPOSED ADDITION TO EXISTING STRUCTURE AT WALLS AND |
| | ROOFING AREAS. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | 6- CLARIFY SHEET S1.2: |
| | PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR GABLE |
| | END CONSTRUCTION. IS THERE A RAKED BEAM?. IF SO, |
| | PROVIDE SPECS. SHOW BEAM IN THE ROOF FRAMING PLAN. |
| | SEC. 606 FBC-EXISTING BUILDING. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | 7-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC |
| | 61G20-3.001 FOR |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL. PROVIDE COMPLETE INFORMATION PRIOR TO |
| | INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL PRODUCT |
| | APPROVALS NEED TO BE APPROVED IN WRITING BY DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL): |
| | A)EXTERIOR DOORS. |
| | B)WINDOWS. |
| | C)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE |
| | IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION |
| | SCHEDULE. SEE CITY SAMPLE. |
| | D)SHINGLES. |
| | E)ROOFING UNDERLAYMENT SPECIFIED ON TWO STORY WALL |
| | SECTION. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |